HP Surestore 64 HP Surestore Director FC-64 SNMP Support Manual - Page 44

The configuration table displays the configuration parameters of the F_Ports., Table 2-20

Page 44 highlights

The configuration table displays the configuration parameters of the F_Ports. Table 2-20 Configuration Table Variable ModuleIndex Provides: Module index. FxPortIndex Name FC-PHVersHigh FC-PHVersLow Port index. Name identifier of the F_Port. Each F_Port has a unique port name in the address space of the fabric. Highest or most recent version of FC-PH that the F_Port is configured to support. Lowest or earliest version of FC-PH that the F Port is configured to support. BBCredit RxBufferSize Total number of receive buffers available for holding a class 1 connect-request, or class 2 or 3 frames from the attached N_Port. It is for buffer-to-buffer flow control in the direction from the attached N_Port (if applicable) to the F_Port. Largest Data_Field size (in octets) for an FT 1 frame that can be received by the F_Port. R_A_TOV E_D_TOV ClassSvcSupt IntermixSupt Resource allocation time out value configured for the F_Port. This is used as the timeout value for determining when to reuse an N_Port resource such as a Recovery_Qualifier. It represents E_D_TOV (see next variable) plus twice the maximum time a frame may be delayed within the fabric and still be delivered. Error detect time out value configured for the F_Port. The Error_Detect_Timeout Value is used as the timeout value for detecting an error condition. Value indicating the set of classes of service supported by the F_Port. Flag indicating if the F_Port supports an intermixed dedicated connection. The flag is always at no(2). StackedConMode Value indicating the mode of stacked connect supported by the F_Port. The value is always at none(1). C2SeqDelivery Flag indicating if class 2 sequential delivery is supported by the F_Port. C3SeqDelivery Flag indicating if class 3 sequential delivery is supported by the F_Port. HoldTime Maximum time (in microseconds) the F_Port holds a frame before discarding the undeliverable frame. The value 0 means that the F_Port does not support this parameter. BaudRate FC-0 baud rate of the F_Port. 38

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

38
±±±±±±±±)LEUH±&KDQQHO±)DEULF±(OHPHQW±0,%±6XSSRUW
The configuration table displays the configuration parameters of the F_Ports.
Table 2-20
Configuration Table
Variable
Provides:
ModuleIndex
Module index.
FxPortIndex
Port index.
Name
Name identifier of the F_Port. Each F_Port has a unique port name in the address space of the
fabric.
FC-PHVersHigh
Highest or most recent version of FC-PH that the F_Port is configured to support.
FC-PHVersLow
Lowest or earliest version of FC-PH that the F Port is configured to support.
BBCredit
Total number of receive buffers available for holding a class 1 connect-request, or class 2 or 3
frames from the attached N_Port. It is for buffer-to-buffer flow control in the direction from the
attached N_Port (if applicable) to the F_Port.
RxBufferSize
Largest Data_Field size (in octets) for an FT 1 frame that can be received by the F_Port.
R_A_TOV
Resource allocation time out value configured for the F_Port. This is used as the timeout value
for determining when to reuse an N_Port resource such as a Recovery_Qualifier. It represents
E_D_TOV (see next variable) plus twice the maximum time a frame may be delayed within the
fabric and still be delivered.
E_D_TOV
Error detect time out value configured for the F_Port. The Error_Detect_Timeout Value is used
as the timeout value for detecting an error condition.
ClassSvcSupt
Value indicating the set of classes of service supported by the F_Port.
IntermixSupt
Flag indicating if the F_Port supports an intermixed dedicated connection. The flag is always at
no(2).
StackedConMode
Value indicating the mode of stacked connect supported by the F_Port. The value is always at
none(1).
C2SeqDelivery
Flag indicating if class 2 sequential delivery is supported by the F_Port.
C3SeqDelivery
Flag indicating if class 3 sequential delivery is supported by the F_Port.
HoldTime
Maximum time (in microseconds) the F_Port holds a frame before discarding the undeliverable
frame. The value 0 means that the F_Port does not support this parameter.
BaudRate
FC-0 baud rate of the F_Port.