IBM 2367 Hardware Maintenance Manual - Page 93
that the connector, If the ThinkPad computer you are servicing has the touch
View all IBM 2367 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 93 highlights
Removing and replacing a FRU If the ThinkPad computer you are servicing has the touch pad, detach the connector a before removing the screws. 5 4 3 3 5 a Step 3 Screw (quantity) M2.5 × 16 mm, nylon-coated (2) 4 M2 × 16 mm, nylon-coated (2) 5 M2.5 × 4.8 mm, nylon-coated (2) Torque 0.392 Nm (4 kgfcm) 0.245 Nm (2.5 kgfcm) 0.392 Nm (4 kgfcm) When installing: If the ThinkPad computer you are servicing has the touch pad, make sure that the connector a is firmly attached. (continued) ThinkPad T30 89
If the ThinkPad computer you are servicing has the touch
pad, detach the connector
±a²
before removing the screws.
3
4
5
5
3
a
Step
Screw (quantity)
Torque
±3²
M2.5 × 16 mm, nylon-coated (2)
0.392 Nm
(4 kgfcm)
±4²
M2 × 16 mm, nylon-coated (2)
0.245 Nm
(2.5 kgfcm)
±5²
M2.5 × 4.8 mm, nylon-coated (2)
0.392 Nm
(4 kgfcm)
When installing:
If the ThinkPad computer you are
servicing has the touch pad, make sure
that the connector
±a²
is firmly attached.
(continued)
Removing and replacing a FRU
ThinkPad T30