IBM 84802AX Installation Guide - Page 14

Features and specifications - computers

Page 14 highlights

Features and specifications The following table provides a summary of the features and specifications of your xSeries 205 Type 8480 server. Depending on your server model, some features and specifications might not apply. Table 1. Features and Specifications Microprocessor: Supports one microprocessor - Intel® Pentium® 4 with 128 KB, 256 KB, or 512 KB Level2 cache and 400 MHz or 533 MHz front side bus (FSB) Memory: • Minimum: 128 MB • Maximum: 2.0 GB • Type: PC2100 266 MHz double- density RAM (DDR) DIMMs • Slots: Two dual inline Drives: (depending on your model) • Diskette: 1.44 MB • Hard disk drive: IDE or SCSI • One of the following: - CD-ROM: IDE - DVD-ROM: IDE - CD-RW: IDE Expansion bays: (depending on your model) • Two 5.25-in. bays (one CD-ROM drive installed) • Two 3.5-in. bays (one diskette drive installed) • Three 3.5-in. hard disk drive bays: hot-swap drive bays (some models) or non-hot-swap drive bays with a hard disk drive installed (some models) PCI expansion slots: • Three 33 MHz/32-bit on the system board (some models come with a SCSI adapter installed) • Two 33 MHz/32-bit on the PCI extender board Video controller: ATI Rage XL video controller with 16 MB SDRAM video memory on the PCI extender card Power supply: One 340 watt (90-240 V ac) Size: • Height: 470 mm (18.5 in.) • Depth: 508 mm (19.9 in.) • Width: 165 mm (6.5 in.) • Weight: approximately 19.5 kg (43 lb) when fully configured or 15.9 kg (35 lb) minimum Integrated functions: • Broadcom 5702 10/100/1000 Ethernet controller on the system board with RJ-45 Ethernet connector • Two serial ports • Parallel port • Two USB ports • Keyboard port • Mouse port • Audio ports - Line out - Line in - Mic • Dual-channel bus mastering IDE controller • Support for IBM Remote Supervisor adapter Acoustical noise emissions: • Sound power, idling: 5.1 bel maximum • Sound power, operating: 5.3 bel maximum Environment: • Air temperature: - Server on: 10° to 35° C (50.0° to 95.0° F). Altitude: 0 to 2133 m (6998.0 ft) - Server off: 10° to 43° C (50.0° to 109.4° F). Maximum altitude: 2133 m (6998.0 ft) • Humidity: - Server on: 8% to 80% - Server off: 8% to 80% Heat output: Approximate heat output in British thermal units (Btu) per hour: • Minimum configuration: 341 Btu (100 watts) • Maximum configuration: 1604 Btu (470 watts) Electrical input: • Sine-wave input (50-60 Hz) required • Input voltage low range: - Minimum: 90 V ac - Maximum: 137 V ac • Input voltage high range: - Minimum: 180 V ac - Maximum: 265 V ac • Input kilovolt-amperes (kVA) approximately: - Minimum: 0.095 kVA - Maximum: 0.470 kVA Notes: 1. Power consumption and heat output vary depending on the number and type of optional features installed and the powermanagement optional features in use. 2. These levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual sound-pressure levels in a given location might exceed the average values stated because of room reflections and other nearby noise sources. The declared soundpower levels indicate an upper limit, below which a large number of computers will operate. 2 Book Title

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

2
Book Title
Features and specifications
The following table provides a summary of the features and specifications of your
xSeries 205 Type 8480 server. Depending on your server model, some features and
specifications might not apply.
Table 1. Features and Specifications
Microprocessor:
Supports one
microprocessor — Intel
®
Pentium
®
4
with 128 KB, 256 KB, or 512 KB Level-
2 cache and 400 MHz or 533 MHz front
side bus (FSB)
Memory:
Minimum: 128 MB
Maximum: 2.0 GB
Type: PC2100 266 MHz double-
density RAM (DDR) DIMMs
Slots: Two dual inline
Drives:
(depending on your model)
Diskette: 1.44 MB
Hard disk drive:
IDE or SCSI
One of the following:
CD-ROM: IDE
DVD-ROM:
IDE
CD-RW:
IDE
Expansion bays:
(depending on your
model)
Two 5.25-in. bays (one CD-ROM
drive installed)
Two 3.5-in. bays (one diskette drive
installed)
Three 3.5-in. hard disk drive bays:
hot-swap drive bays (some
models) or non-hot-swap drive
bays with a hard disk drive
installed (some models)
PCI expansion slots:
Three 33 MHz/32-bit on the
system board (some models come
with a SCSI adapter installed)
Two 33 MHz/32-bit on the PCI
extender board
Video controller:
ATI Rage XL video
controller with 16 MB SDRAM video
memory on the PCI extender card
Power supply:
One 340 watt (90-240
V ac)
Size:
Height: 470 mm (18.5 in.)
Depth: 508 mm (19.9 in.)
Width: 165 mm (6.5 in.)
Weight: approximately 19.5 kg
(43 lb) when fully configured or
15.9 kg (35 lb) minimum
Integrated functions:
Broadcom 5702 10/100/1000
Ethernet controller on the system
board with RJ-45 Ethernet
connector
Two serial ports
Parallel port
Two USB ports
Keyboard port
Mouse port
Audio ports
Line out
Line in
Mic
Dual-channel bus mastering IDE
controller
Support for IBM Remote
Supervisor adapter
Acoustical noise emissions:
Sound power, idling: 5.1 bel
maximum
Sound power, operating: 5.3 bel
maximum
Environment:
Air temperature:
Server on: 10
°
to 35
°
C
(50.0
°
to 95.0
°
F). Altitude: 0
to 2133 m (6998.0 ft)
Server off: 10° to 43
°
C
(50.0
°
to 109.4
°
F). Maximum
altitude: 2133 m (6998.0 ft)
Humidity:
Server on: 8% to 80%
Server off: 8% to 80%
Heat output:
Approximate heat output
in British thermal units (Btu) per hour:
Minimum configuration: 341 Btu
(100 watts)
Maximum configuration: 1604 Btu
(470 watts)
Electrical input:
Sine-wave input (50-60 Hz) required
Input voltage low range:
Minimum: 90 V ac
Maximum: 137 V ac
Input voltage high range:
Minimum: 180 V ac
Maximum: 265 V ac
Input kilovolt-amperes (kVA)
approximately:
Minimum: 0.095 kVA
Maximum: 0.470 kVA
Notes:
1.
Power consumption and heat
output vary depending on the
number and type of optional
features installed and the power-
management optional features in
use.
2.
These levels were measured in
controlled acoustical environments
according to the procedures
specified by the American National
Standards Institute (ANSI) S12.10
and ISO 7779 and are reported in
accordance with ISO 9296.
Actual
sound-pressure levels in a given
location might exceed the average
values stated because of room
reflections and other nearby noise
sources.
The declared sound-
power levels indicate an upper limit,
below which a large number of
computers will operate.