IBM 84802AX Installation Guide - Page 34

Check the hard disk drive status LED to verify that the hard disk drive is

Page 34 highlights

Attention: • When you handle static-sensitive devices, take precautions to avoid damage from static electricity. For details on handling these devices, see "Handling staticsensitive devices" on page 6. • To maintain proper system cooling, do not operate the server for more than 10 minutes without either a drive or a filler panel installed in each bay. Complete the following steps to install a hot-swap hard disk drive in bay 5, 6, or 7. Note: You do not have to turn off the server to install hot-swap hard disk drives in these bays. 1. Read the information in "Preinstallation steps (all bays)" on page 15. 2. Remove the filler panel from one of the empty hot-swap bays by inserting your finger into the depression at the left side of the filler panel and pulling it away from the server. 3. Install the hard disk drive in the hot-swap bay: a. Ensure that the tray handle is open (that is, perpendicular to the drive). b. Align the drive-tray assembly with the guide rails in the bay. c. Gently push the drive-tray assembly into the bay until the drive stops. d. Push the tray handle to the closed (locked) position. Filler panel Drive tray assembly Drive tray handle (in open position) e. Check the hard disk drive status LED to verify that the hard disk drive is operating properly. If the amber disk drive status LED for the drive is lit continuously, that individual drive is faulty and needs to be replaced. If the green hard disk drive activity LED is flashing, the drive is being accessed. Note: If you install a RAID adapter in your server, you might need to reconfigure your disk arrays after installing hard disk drives. See the information that comes with your RAID adapter. 4. If you have other options to install, do so now. 22 Book Title

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

22
Book Title
Attention:
When you handle static-sensitive devices, take precautions to avoid damage from
static electricity.
For details on handling these devices, see “Handling static-
sensitive devices” on page 6.
To maintain proper system cooling, do not operate the server for more than 10
minutes without either a drive or a filler panel installed in each bay.
Complete the following steps to install a hot-swap hard disk drive in bay 5, 6, or 7.
Note:
You do not have to turn off the server to install hot-swap hard disk drives in
these bays.
1.
Read the information in “Preinstallation steps (all bays)” on page 15.
2.
Remove the filler panel from one of the empty hot-swap bays by inserting your
finger into the depression at the left side of the filler panel and pulling it away from
the server.
3.
Install the hard disk drive in the hot-swap bay:
a.
Ensure that the tray handle is open (that is, perpendicular to the drive).
b.
Align the drive-tray assembly with the guide rails in the bay.
c.
Gently push the drive-tray assembly into the bay until the drive stops.
d.
Push the tray handle to the closed (locked) position.
e.
Check the hard disk drive status LED to verify that the hard disk drive is
operating properly.
If the amber disk drive status LED for the drive is lit continuously, that
individual drive is faulty and needs to be replaced.
If the green hard disk drive
activity LED is flashing, the drive is being accessed.
Note:
If you install a RAID adapter in your server, you might need to reconfigure
your disk arrays after installing hard disk drives.
See the information that
comes with your RAID adapter.
4.
If you have other options to install, do so now.
Filler panel
Drive tray
assembly
Drive tray handle
(in open position)