Icom IC-M412 Instruction Manual - Page 43

Receiving a Distress Relay call, Receiving a Distress Relay Acknowledgement

Page 43 highlights

DSC OPERATION 6 D Receiving a Distress Relay call When a Distress Relay is received: ➥ The emergency alarm sounds for 2 minutes. • Push any key to stop the alarm. ➥ "DSC" appears and "RCV RELAY" scrolls in the channel com- ment display, then Channel 16 is automatically selected. This action can be changed, depending on the combination of the Auto Switch function and Auto Tune timer settings. See pages 39 and 40 for more details. Scrolls Appears 1 D Receiving a Distress Relay Acknowledgement 2 When a Distress Relay acknowledgement is received: 3 ➥ The emergency alarm sounds for 2 minutes. • Push any key to stop the alarm. 4 ➥ "DSC" appears and "RCV RELAY ACK" scrolls in the channel 5 comment display, then Channel 16 is automatically selected. This action can be changed, depending on the combi- 6 nation of the Auto Switch function and Auto Tune timer 7 settings. See pages 39 and 40 for more details. 8 9 Scrolls 10 Appears 11 NOTE: The alarm sounds when duplicate distress relay or 12 distress relay acknowledgement call for individual is received within 1 hour. 13 14 15 16 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

35
6
DSC OPERATION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
D
Receiving a Distress Relay call
When a Distress Relay is received:
The emergency alarm sounds for 2 minutes.
• Push any key to stop the alarm.
DSC
” appears and “RCV RELAY” scrolls in the channel com-
ment display, then Channel 16 is automatically selected.
This action can be changed, depending on the combi-
nation of the Auto Switch function and Auto Tune timer
settings. See pages 39 and 40 for more details.
Scrolls
Appears
D
Receiving a Distress Relay Acknowledgement
When a Distress Relay acknowledgement is received:
The emergency alarm sounds for 2 minutes.
• Push any key to stop the alarm.
DSC
” appears and “RCV RELAY ACK” scrolls in the channel
comment display, then Channel 16 is automatically selected.
This action can be changed, depending on the combi-
nation of the Auto Switch function and Auto Tune timer
settings. See pages 39 and 40 for more details.
Scrolls
Appears
NOTE:
The alarm sounds when duplicate distress relay or
distress relay acknowledgement call for individual is re-
ceived within 1 hour.