EXPOSURE Screen, Settings in bold are factory settings
UPC - 046838326004
View all JVC KY-F560U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
"EXPOSURE" Screen Settings in bold are factory settings Item "IRIS MODE" "MANUAL LEVEL" "GAIN" "LEVEL" Function/Variable Values Switch according to the lens in use. "AUTO" : When using auto iris lens "MANUAL" : When using manual iris lens For setting the iris level when "IRIS MODE" is set to "MANUAL". Increase value : Opens the iris. Decrease value : Closes iris. {Variable Values : 0 - 128 - 255} Note "When "IRIS MODE" is set to "AUTO", "MANUAL LEVEL" item selection will be disabled. (Displayed as For switching the electric sensitivity mode. "STEP" : Gain boost level can be altered using the "LEVEL" item. "V.GAIN" : Gain boost level can be fine-tuned using the "LEVEL" item. "ALC" : Alters gain boost level automatically according to the brightness. Set the maximum value at the "ALC LIMIT" item. ☞ Page 33 Gain boost level can be altered when gain boost mode is set as "STEP" or "V.GAIN". {Variable "STEP" Values: -3, 0, +3, +6, +9, +12, +15, +18dB, LOLUX} {Variable "V.GAIN" Values: -3 - 0 - 18dB 0.2dB Step} Note "When "GAIN" is set to "ALC", "LEVEL" item selection will be disabled. (Displayed as 31