JVC KY-F70U KY-F70U Computer Imaging Camera Instructions (827KB)
JVC KY-F70U - Sxga Imaging Camera Less Lens Manual
View all JVC KY-F70U manuals
Add to My Manuals
Save this manual to your list of manuals |
JVC KY-F70U manual content summary:
- JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 1
Introduction Before recording Digital Camera Model KY-F70 Settings and adjustments for recording INSTRUCTIONS C-MOUNT DIGITAL CAMERA KY-F70 Basic operations Various recording methods Menu screen settings Illustration with optional lens attachment. Connecting to a PC For Customer Use: Enter - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 2
point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. INFORMATION (FOR CANADA) RENSEIGNEMENT (POUR CANADA) • This Class B digital apparatus complies with - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 3
WARNING ON LITHIUM BATTERY The battery used in this device may present a fire or chemical burn hazard if mistreated. Do not recharge, disassemble, heat avobe 100°C or incinerate. Replace battery with Panasonic (Matsushita Electric). CR2032, use of another battery may present a risk of fire or - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 4
Table of Contents 1. Introduction Features ...6 Accessories and attachments 6 Cautionary notes for the correct usage of this product 7 Part names and their functions 8 Explanation of terminals 12 2. Before recording Basic system 1 ...14 @ B@asi@c sy@ste@m [email protected] Inserting the lithium battery - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 5
...62 7. Connecting to a PC Compatible systems 1 ...64 Compatible systems 2 ...65 8. Others Specifications ...66 Characters and symbols used in this instruction book CAUTION MEMO ੬ Cautionary notes concerning operation of the unit Reference such as restrictions of features, etc. Reference page or - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 6
(10-pin) REMOTE terminal plug ( ੬ page 12) Battery For time and date backup ( ੬ page 16) Ferrite core For power cable ( ੬ page 18) Instruction book Warranty card E6 Mini screwdriver For replacing battery ( ੬ page 16) PC software (2 types) • Remote control software (For controlling the main unit - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 7
the purpose of preventing electrical interference in residential areas. However, using the product near televisions and radios may cause interference of reception. Please read the instructions carefully for the correct usage. E7 - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 8
1. Introduction (continued) Part names and their functions [Front and bottom] @@@@@@ C-MOUNT DIGITAL CAMERA KY-F70 ^ Lens mount Although the lens mount conforms to the type C mount lens, there are restrictions on the lenses that can be used. Mounting the lens ( ੬ page 17) _ Camera mounting - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 9
[Rear] SCSI REC SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE MONITOR LENS REMOTE ON 1 2 3 4 DC IN POWER SEE INSTRUCTION MANUAL c MENU button Press this button to output the menu screen from the MONITOR terminal. Press the button once more to clear the menu screen. Setting - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 10
)] Ventilation hole @@@@@@ SCSI REC SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE MONITOR LENS REMOTE ON 1 2 3 4 DC IN POWER SEE INSTRUCTION MANUAL f MODE/SET button ● [MODE] Pressing this button each time will switch between the REC (record)* and PLAY (playback) modes. The default mode - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 11
i FREEZE button While in the REC mode, press this button to capture a still image (freeze) of the images being outputted through the MONITOR terminal. At the same time, the still image is saved to the main unit memory. Pressing this button once more will cancel the still image and return to the - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 12
1. Introduction (continued) Explanation of terminals Power terminal (Mini DIN 8-pin, female) 7 8 6 5 3 2 4 1 @@@@@@ Pin no. Signal name 1 NC 2 GND 3 NC 4 NC 5 GND 6 12V 7 NC 8 12V Remoter terminal (Metal 10-pin, female) 8 7 1 2 10 9 6 5 3 4 Pin no. 1 2 3 4 5 6 7 - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 13
Monitor terminal (D-sub 15-pin, female) SCSI terminal (Half-pitch 50-pin, female) 5 1 25 1 10 6 15 11 Pin no. 1 2 3 4 5 Signal name R OUT 700mV, 75 Ω G OUT 700mV, 75 Ω B OUT 700mV, 75 Ω GND NC 6 R GND 7 G GND 8 B GND 9 NC 10 GND 11 GND 12 NC 13 Hs (3V(p-p) negative polarity - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 14
2. Before recording Basic system 1 While checking the images from the camera on the monitor, output the images to an MO disk or printer. Connect to the power supply ( ੬ page 18) @@@@@@ AA-P700 AC ADAPTER AA-P700 POWER ON OFF AC adapter MONITOR SCSI Connect the monitor AC ( ੬ page 19) VIDEO IN - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 15
Basic system 2 This is a system to record with this camera using a flash timed by an external freeze switch. AA-P700 AC ADAPTER AA-P700 POWER ON OFF AC AC adapter MONITOR SCSI REMOTE REMOTE DC IN VGA monitor DIGITAL CAMERA KY-F70 C-MOUNT Model name Microscope adapter ,Flash MO disk drive - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 16
2. Before recording (continued) Inserting the lithium battery The lithium battery is used to back up the time and date data. Install the lithium battery before using the unit. < Install > Mini screwdriver (attached) Screws 1. @@@@@@ Battery compartment DIGITAL CAMERA KY-F70 2. 5 C-MOUNT - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 17
Mounting the lens Follow the procedure shown below when mounting an auto-iris lens. For further details, see the instruction manual of the lens. Camera head 3. Male Thread section Mount clamp ring Lens 2. C-MOUNT DIGITAL CAMERA KY-F70 Female Lens remote control 1. Remove the lens mount - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 18
attached power supply cable (2m). @ @ @ @ @ @AC 100V AA-P700 DC 12V=OUTPUT VIDEO OUTPUT AC S(Y/C) OUTPUT TO CAMERA EITHER OUTPUT MAX 1.25A AC adapter SEE INSTRUCTION MANUAL SCSI REC SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE MONITOR LENS REMOTE ON 1 2 3 4 DC IN POWER SEE - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 19
rear of the main unit. SCSI REC SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE MONITOR LENS REMOTE ON 1 2 3 4 DC IN POWER SEE INSTRUCTION MANUAL MONITOR terminal ● Before connecting, make sure that the power of all systems are turned off. Connecting with the power turned on may result in - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 20
an MO disk) Dip switches @@@@@@ SCSI REC SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE MONITOR LENS REMOTE ON 1 2 3 4 DC IN POWER SEE INSTRUCTION MANUAL SCSI terminal To directly connect the MO drive to the main unit, set the dip switches on the rear of the main unit as shown - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 21
] COPY ONLINE POWER OPEN SCSI REC SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE MONITOR LENS REMOTE ON 1 2 3 4 DC IN POWER SEE INSTRUCTION MANUAL SCSI terminal When directly connecting the main unit to a printer, set the dip switches on the rear of the main unit as shown below. ON - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 22
2. Before recording (continued) Mounting the camera < Mounting method > Rotation prevention hole Camera mounting screw hole @@@@@@ Camera mounting bracket ● When mounting the camera, use the camera mount screw hole located on the camera mounting bracket. ● When mounting the camera, use the - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 23
Fall prevention Fall prevention wire chain 6mm Camera head C-MOUNT DIGITALCAMERA KY-F70 Notes ● Special attention is required when mounting the unit to the wall or ceiling. Rather than attempting to do it yourself, request a qualified person to perform such installation. Falling of the unit - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 24
switches. SCSI REC SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE MONITOR LENS Dip switches @@@@ REMOTE ON 1 2 3 4 DC IN POWER @ @ SEE INSTRUCTION MANUAL MEMO Turn the power off before setting the dip switches. Setting the switches with the power on will not change the settings. Monitor - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 25
mode by the rear dip switches, disabling changes. Lens settings Set whether the used lens is an auto-iris lens or a manual lens. - - - EXPOSURE - - - I R I S MODE AE LEVEL I R I S LEVEL I R I S DETECT I R I S AREA SHUT TER SPEED SENCET I V I TY LEVEL A LC MAX : AUTO :0 : 128 : NORMA L : FULL - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 26
MODE/SET SCSI REC SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE MONITOR LENS @@@@@@ REMOTE DC IN ON 1 2 3 4 POWER SEE INSTRUCTION MANUAL PLAY - - - SYSTEM MENU - - - ON SCREEN : MEMORY NUM SEND PR I OR ITY : MO BAR LEVEL : 0.7 V MENU RESET . . V I DEO MEMORY CL EAR . . T I ME AD - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 27
- - - T I ME AD J UST - - OK 6. OK will be displayed for approximately 3 seconds and the unit will return to the menu screen. OK display screen MEMO When setting the time and date, always set the seconds (00). Pressing the MENU button before setting the seconds will not change the set values. E27 - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 28
the power on will not change the settings. 4. Turn the main unit power on. 5. Adjust the video monitor. MEMO • For the adjustment method, see the instruction manual of the video monitor. • The peak level of the color bar is et to 0.7V. To change the setting to 0.58V, select BAR LEVEL in - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 29
Focus adjustment This unit is not equipped with a back-focus feature. Adjust the back focus using the lens. Male Focus ring C-MOUNT DIGITAL CAMERA KY-F70 Female Shutter speed - - - REC MENU ( QU I CK ) - - - AE LEVEL :0 I R I S LEVEL : 1 2 8 SHU T ERE : STEP SPEED : 1 / 30 SENS I T I V - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 30
UP MODE/SET SCSI @ @ @ @ @ @ REC SEND AW/SEL MODE REC LED MENU UP DOWN SET PLAY FREEZE MONITOR LENS REMOTE ON 1 2 3 4 DC IN POWER SEE INSTRUCTION MANUAL 1. Press the MODE button to enter the REC mode (REC LED on), then press and hold the MENU button for at least 2 seconds to display - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 31
AW SCSI REC SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE MONITOR LENS REMOTE ON 1 2 3 4 DC IN POWER SEE INSTRUCTION MANUAL AUTO WH I TE O PERA T I O N Auto white in operation AUTO W H I TE OK Auto white operation completed 6. After pressing the MENU button twice to return to the - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 32
SCSI REC SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE MONITOR LENS REMOTE ON 1 2 3 4 DC IN POWER SEE INSTRUCTION MANUAL REC LED - - -REC MENU - - - 1 : EXPOSURE . . 2 : WH I TE BA L ANCE . . 3 : FREEZE . . 4 : PROCESS . . 5 : SYSTEM SET T I NG . . Perform the following after adjusting the - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 33
- - - WHI TE BA LANCE - - - COLOR TEMP : 3 2 0 0 K WH I TE BA L : AUTO LEVEL ( R ) :0 LEVEL ( B ) :0 SHAND I NG MODE: AD JUST LEVEL ( R ) :0 LEVEL ( G ) :0 LEVEL ( B ) :0 WHITE BALANCE screen 4. While watching the monitor screen, change LEVEL (R), LEVEL (G) and LEEL (B) using the UP - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 34
MODE @ @ @ @ @ @ SCSI REC SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE MONITOR LENS REC LED FREEZE REMOTE ON 1 2 3 4 DC IN POWER SEE INSTRUCTION MANUAL 1. Press the MODE button to enter the REC mode. The REC LED will light. MEMO The unit will automatically enter the REC mode when the - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 35
or DRAFT mode. SEL MODE SCSI REC SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE MONITOR LENS REMOTE ON 1 2 3 4 DC IN POWER SEE INSTRUCTION MANUAL PLAY LED 1. Press the MODE button to enter the PLAY mode. The PLAY LED will light and the latest image stored will be displayed on - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 36
@ SCSI @@@ REC SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE MONITOR LENS REMOTE ON 1 2 3 4 DC IN OPNOWE1R 2 3 4 Undefined SEE INSTRUCTION MANUAL Dip switches WR I T E TO MO OK ? OK : " MODE " CANCE L: " MENU " Output confirmation WR I T E TO MO OPER AT I O N Ⅵ Set to either the - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 37
Outputting images from the memory to a printer Use a printer with an SCSI input terminal. It is possible to directly output images stored in the main unit memory to a printer connected via the SCSI terminal when in the FREEZE or PLAY mode. (To output to a printer connected to a PC, see Page 64 7. - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 38
1. Press the MODE button to enter the PLAY mode (PLAY LED on), then press the MENU button to display the MENU screen. SEE INSTRUCTION MANUAL - - - P- L AY / FREEZE MENU - - ON SCREEN : MEMORY NUM SEND PR I OR I T : MO BAR L EVE L : 0.7 V MENU RESET . . V I DEO MEMORY CL EAR . . T I ME AD J UST - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 39
V I DEO MEMORY C L EA R OK Memory cleared 4. When completed, VIDEO MEMORY CLEAR OK will ap- pear for approximately 3 seconds and the unit will return to the MENU screen. MEMO After clearing the entire memory in the PLAY mode, the unit will automatically enter the REC mode since no images will be - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 40
5. Various recording methods Recording a PC monitor Horizontal line noise will appear on the screen when attempting to record images on a PC monitor or display. To clear this noise, the main unit shutter speed must be adjusted with scan speed of the monitor. @@@@@@ 1. Press the MODE button to - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 41
SCSI REC SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE MONITOR LENS REMOTE ON 1 2 3 4 DC IN POWER SEE INSTRUCTION MANUAL REC LED MONITOR terminal - - - REC MENU - - - 1 : EXPOSURE . . 2 : WH I TE BA L ANCE . . 3 : FREEZE . . 4 : PROCESS . . 5 : SYSTEM SET T I NG . . 2. Use the DOWN button - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 42
not recognized and FREEZE input interval for high speed shutters also require a minimum of 2 frames (270ms). ● When the FREEZE cancel mode is set to MANUAL, the FREEZE input for FREEZE cancellation will not output a FLASH signal or WEN. E42 Timing chart (SXGA mode) FREEZE VD (Internal) EXP (CCD - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 43
range of 2 graduations of the aperture under dark lighting and 5 graduations when in FINE under bright lighting. When the iris is set to manual, the sensitivity and electronic shutter are continuously changed without changing the iris setting. This feature holds the advantage of being able to record - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 44
6. Menu screen settings Menu screen flow There are 3 types of menu screens: PLAY menu screen, REC quick menu screen and REC normal menu screen. Normal screen Lightly press the @ @ @ @ @ME@NU button (less than 2 seconds) while in the REC mode. - - -REC MENU ( QU I CK ) - - - AE LEVEL :0 I R I - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 45
R ) :0 LEVEL ( B ) :0 SHAND I NG MODE: OF F LEVEL ( R ) : LEVEL ( G ) : LEVEL ( B ) : WHITE BALANCE screen - - - FREEZE - - - CANCE L : MANUAL FREEZE screen - - - PROCESS ( 1 / 3 ) - - - DETA I L : ADJUST LEVEL :0 H FREQUENCY : H I GH L EVE L DEP : 0.0% GAMMA : NORMAL LEVEL - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 46
SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE REC LED MONITOR LENS @@@@@@ REMOTE DC IN ON 1 2 3 4 POWER SEE INSTRUCTION MANUAL Menu item - - - REC MENU - - - 1 : EXPOSURE . . 2 : WH I TE BA L ANCE . . 3 : FREEZE . . 4 : PROCESS . . 5 : SYSTEM SET T I NG . . REC normal menu screen Menu - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 47
- - - P L AY / FREEZE MENU - - ON SCREEN : MEMORY NUM SEND PR I ORI TY: MO BAR L EVE L : 0.7 V MENU RESET . . V I DEO MEMORY CL EAR . . T I ME AD J UST . . PLAY menu screen PLAY menu screen 1. Enter the PLAY or FREEZE mode, then press the MENU button to display the PLAY menu screen. 2~5. Follow the - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 48
(continued) EXPOSURE screen Menu item IRIS MODE Function/variable range Set depending on the used lens AUTO: when using an auto-iris lens MANUAL: when using a manual iris lens or no lens Default value ATUO AE LEVEL Used to adjust the video level when using auto iris, ALC 0 @ @ @ @ @ @and EEI - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 49
EXPOSURE screen (continued) Menu item SHUTTER SPEED Function/variable range Default value Used to set the shutter mode. STEP: the shutter speed can be changed using the SPEED submenu item. V.SCAN: used to clear the horizontal line noise when re- cording a PC monitor by adjusting to the scan - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 50
6. Menu screen settings (continued) EXPOSURE screen (continued) Menu item Function/variable range Default value SENSITIVITY Used to set the sensitivity mode. STEP: the sensitivity can be changed using the LEVEL submenu item. ALS: the sensitivity si automatically changed by the @@@@@@ - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 51
be changed using LEVEL (R) and LEVEL (B). AUTO The color red of the white balance can be adjusted when WHITE BALANCE is set to AUTO or MANUAL. Increase the number: stronger red on the screen Decrease the number: weaker red on the screen [Variable range during AUTO: -32 ~ 31] [Variable range during - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 52
temperatures when setting COLOR TEMP and WHITE BALANCE COLOR WHITE TEMP BALANCE PRESET 3200K AUTO @ @ @ @ @MA@NUAL 5200K PRESET AUTO MANUAL 2000K Color temperature 3200K 5200K Default value 15000K SHADING MODE LEVEL (R) LEVEL (G) LEVEL (B) Used to set whether to perform white shading - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 53
: freeze is cancelled by pressing the FREEZE button. AUTO: freeze is automatically cancelled after 5 sec- onds. MANUAL PROCESS (1/3) screen Menu item DETAIL Function/variable range Used to set whether to emphasize details. ADJUST: changes the detail emphasis OFF: no detail emphasis Default - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 54
6. Menu screen settings (continued) PROCESS (1/3) screen (continued) Menu item Function/variable range Default value GAMMA Used to set whether the gamma curve to determine the reproduction of black is to be set using the standard value or available for change. NORMAL: the gamma curve is set - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 55
PROCESS (2/3) screen Menu item FLARE (R) FLARE (B) ABL LEVEL Function/variable range Default value Rch compensation of the black level when flaring effect 0 occurs and the entire screen becomes washed out from the light entering the lens reflecting diffusely. Perform this function along with - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 56
6. Menu screen settings (continued) PROCESS (2/3) screen (continued) Menu item Function/variable range Default value COLOR Used to set whether to change the color matrix or use the MATRIX standard value. OFF: the standard value of the color matrix is used. ADJUST: the color matrix becomes - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 57
SYSTEM SETTING screen Menu item ON SCREEN Function/variable range Default value Used to set the text to display in the video signal output- ted to the MONITOR terminal. ALC EEI: displays ALC and EEI status during the REC mode. MEMORY NUM: displays the memory image number during the PLAY - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 58
6. Menu screen settings (continued) SYSTEM SETTING screen (continued) Menu item BAR LEVEL Function/variable range Default value Used to set the level of the color bar signal outputted from the MONITOR terminal of this unit. 0.7V: outputs 0.7V color bar signals 0.58V: outputs 0.58V color bar - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 59
Menu screen of the PLAY mode Menu item ON SCREEN Function/variable range Default value Used to set the text to display in the video signal output- ted to the MONITOR terminal. ALC EEI: displays ALC and EEI status during the REC mode. MEMORY NUM: displays the memory image number during the - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 60
the level: decrease the number [Variable range: -128 ~ 127] @@@@@@ IRIS LEVEL Used to set the iris level when the IRIS MODE is set to 128 MANUAL. Open iris: increase the number Close iris: decrease the number [Variable range: 0 ~ 255] SHUTTER Used to set the shutter mode. STEP: the shutter - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 61
Menu item SPEED Function/variable range MEMO • In areas which the power supply frequency is 50Hz, set- ting the unit to 1/100 can reduce flickering when recording under florescent lighting. • There may be shortage of light when increasing the shutter speed. In this case, adjust the iris or - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 62
1. Press the MODE button to enter the PLAY mode (PLAY LED on), then press the MENU button to display the MENU screen. SEE INSTRUCTION MANUAL - - - PL AY / FREEZE MENU - - - ON SCREEN : MEMORY NUM SEND PR I OR I T : MO BAR L EVE L : 0.7 V MENU RESET . . V I DEO MEMORY CL EAR . . T I ME AD J UST - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 63
MENU RESET OK Reset completed 4. When all values are reset to their default settings, MENU RESET OK message will appear for 3 seconds, then the unit will return to the MENU screen. 5. Press the MENU once more to return to the normal screen. E63 - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 64
camera remote control software and the SCSI capture plug-in software must be installed to the PC. For details, see the attached instructions of the software. ⅥCamera remote control software • GUI control • RS-232C • SCSI control compatible ⅥSCSI capture plug-in software • Photoshop compatible - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 65
] COPY ONLINE POWER OPEN Printer * For this system, the attached camera remote control software must be installed to the PC. For details, see the attached instructions of the software. E65 - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 66
8. Others Specifications Imaging device: 1/2 inch IT CCD × 3 Scanning method: Progressive scanning Available no. of pixels: 1.45 million pixels (1392 (H) × 1040 (V)) Effective no. of pixels: 1360 × 1024 Color separation method: As@pec@t ra@tio:@ @ @ Dichroic prism method 4:3 V.SCAN: 1/ - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 67
External dimensions (unit: mm) 70 1 150 142.5 C-MOUNT DIGITAL CAMERA KY-F70 88 80 41.5 14 1/4 inch screw Design and specifications are subject to change without notice. E67 - JVC KY-F70U | KY-F70U Computer Imaging Camera Instructions (827KB) - Page 68
VICTOR COMPANY OF JAPAN, LIMITED is a registered trademark owned by VICTOR COMPANY OF JAPAN, LTD. is a registered trademark in Japan, the U.S.A., the U.K. and many other countries. © 1999 VICTOR COMPANY OF JAPAN, LIMITED Printed in Japan SL96172
Digital Camera
Model
KY-F70
INSTRUCTIONS
Illustration with optional lens attachment.
This instruction book is made from 100%
recycled paper.
SC96847-001
KY-F70
CAMERA
DIGITAL
C-MOUNT
For Customer Use:
Enter below the Serial No. which is
located on the unit. Retain this
information for future reference.
Model No.
KY-F70
Serial No.
Introduction
Before recording
Settings and
adjustments
for recording
Basic operations
Various
recording
methods
Menu screen
settings
Connecting
to a PC
Others