6. Menu screen settings (continued) PROCESS (1/3) screen (continued) Menu item Function/variable range Default value GAMMA Used to set whether the gamma curve to determine the reproduction of black is to be set using the standard value or available for change. NORMAL: the gamma curve is set using the standard value (0.45) @ @ @ @ @ @ADJUST: set when changing the gamma curve NORMAL LEVEL The gamma curve can be adjusted only when GAMMA is 0.45 set to ADJUST. Increase the number: improves the reproduction of black. However, the reproduction quality of bright areas becomes lower. Decrease the number: improves the reproduction of bright areas. However, the reproduction quality of black becomes lower. [Variable range: 0.35 ~ 1.00 (21 steps)] MASTER BLACK Used to adjust the pedestal level (master black), which is 0 the standard black during lens cap. To view black areas, increase the pedestal level to brighten the entire screen. Increase the pedestal level: increase the number Decrease the pedestal level: decrease the number [Variable range: -99 ~ 99] E54