Menu item SPEED Function/variable range MEMO • In areas which the power supply frequency is 50Hz, set- ting the unit to 1/100 can reduce flickering when recording under florescent lighting. • There may be shortage of light when increasing the shutter speed. In this case, adjust the iris or sensitivity. Special attention is required for the picture quality when raising the sensitivity since images may become distorted. Default value SENSITIVITY LEVEL ALC MAX Used to set the sensitivity mode. STEP: the sensitivity can be changed using the LEVEL submenu item. ALS: the sensitivity si automatically changed by the brightness. Maximum sensitivity is set in the next ALC MAX menu item. V.SENS: the sensitivity can be set in detail using the LEVEL submenu item. STEP The sensitivity can be changed when the sensitivity mode is set to STEP or V.SENS. [STEP variable range: ISO100, ISO200, ISO400] [V.SENS variable range: ISO100 ~ ISO400] STEP: ISO100 V.SENS: ISO100 This can be set when the sensitivity mode is set to ALC. Used to set the maximum sensitivity of ALC, which automatically switches the sensitivity depending on the brightness. [Variable range: ISO200, ISO400] ISO400 E61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

E61
Menu item
SPEED
SENSITIVITY
LEVEL
ALC MAX
Default value
STEP
STEP:
ISO100
V.SENS:
ISO100
ISO400
Function/variable range
MEMO
In areas which the power supply frequency is 50Hz, set-
ting the unit to 1/100 can reduce flickering when record-
ing under florescent lighting.
There may be shortage of light when increasing the shut-
ter speed. In this case, adjust the iris or sensitivity. Spe-
cial attention is required for the picture quality when rais-
ing the sensitivity since images may become distorted.
Used to set the sensitivity mode.
STEP:
the sensitivity can be changed using the LEVEL
submenu item.
ALS:
the sensitivity si automatically changed by the
brightness. Maximum sensitivity is set in the next
ALC MAX menu item.
V.SENS:
the sensitivity can be set in detail using the
LEVEL submenu item.
The sensitivity can be changed when the sensitivity mode
is set to STEP or V.SENS.
[STEP variable range: ISO100, ISO200, ISO400]
[V.SENS variable range: ISO100 ~ ISO400]
This can be set when the sensitivity mode is set to ALC.
Used to set the maximum sensitivity of ALC, which auto-
matically switches the sensitivity depending on the bright-
ness.