JVC KY-F70U KY-F70U Computer Imaging Camera Instructions (827KB) - Page 24
Settings and adjustments for recording
View all JVC KY-F70U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
3. Settings and adjustments for recording Setting the dip switches The type of PC monitor to use and the ID during SCSI connection are set using the dip switches. SCSI REC SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE MONITOR LENS Dip switches @@@@ REMOTE ON 1 2 3 4 DC IN POWER @ @ SEE INSTRUCTION MANUAL MEMO Turn the power off before setting the dip switches. Setting the switches with the power on will not change the settings. Monitor settings Dip switch no. 3 is set depending on whether the PC monitor being used is a VGA monitor or a SXGA monitor. ON 1 2 3 4 Set to OFF ON 1 2 3 4 Set to ON VGA output terminal Set when directly connecting a VGA monitor to the MONITOR terminal on the rear of the main unit. SXGA output setting Set for systems using a SXGA monitor. The signal from the MONITOR terminal on the rear of the main unit is inputted through the analog input compatible video capture board. ( ੬ Page 65 Compatible systems 2) SCSI ID settings Sid switches 1 and 2 are set depending on the used system to set the SCSI ID. ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ID=7 ID=6 ID=5 ID=4 E24 Set when connecting a printer or MO drive directly to the main unit. When making this setting, the main unit will become the host (initiator). Set when exporting images to a PC. Make sure that the ID numbers of the connecting devices are not the same. When making this setting, the PC will become the host (initiator) and the main unit will become the target. ( ੬ Page 64 Connecting to a PC)