Kenmore 5814 Use and Care Guide - Page 22

Performance Data Sheet

Page 22 highlights

PERFORMANCE DATA SHEET @ Base Grille Water Filtration System Model TIKB1/TIRFKB1 Capacity 100 Gallons (379 Liters) System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSl Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos, Lindane, Tetrachloroethylene, Endrin, Alachlor, Chlorobenzene, Ethylbenzene, TI-HM, MTBE and VOC. This system has been tested according to NSF/ANSl Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSl Standards 42 and 53. Substance Reduction NSF Reduction Average Aesthetic Effects Requirements Influent Influent Challenge Concentration Maximum Effluent Average Effluent Minimum % Average % Reduction Reduction Chlorine Taste/Odor Particulate Class I* Contaminant Reduction Lead: @ pH 6.5 Lead: @ pH 8.5 Mercury: @ pH 6.5 Mercury: @ pH 8.5 Benzene 50% reduction 85% reduction NSF Reduction Requirements 0.010 rng/L 0.010 mg/L 0.002 mg/L 0.002 mg/L 0.005 mg/L 2.0 mg/L 3533333#/mL Average Influent 150 ug/L 157 ug/L 0.0058 mg/L 0.0057 mg/L 15 ug/L 2.0 mg/L _+10% At east 10,000 part c es/mL Influent Challenge Concentration 0.08 mg/L 22000 #/mL** Maximum Effluent 0.15 mg/L _+10% 0.15 mg/L _+10% 1.0 ug/L 2.0 ug/L 0.006 mg/L _+10% 0.006 mg/L _+10% 0.0002 mg/L 0.0002 mg/L 0.015 mg/L _+10% 0.5 ug/L 2.0 mg/L 11567 #/mL Average Effluent 1 ug/L 1.08 ug/L 0.0002 mg/L 0.0002 mg/L 0.5 ug/L 95.93 99.38 Minimum % Reduction 99.33 98.72 96.53 96.5 96.67 97.36 99.67 Average % Reduction 99.33 99.31 96.53 96.5 96.67 O-Dichlorobenzene Toxaphene Atrazine Asbestos 0.6 mg/L 0.003 mg/L 0.003 mg/L 99% 1750 ug/L 15 ug/L 10 ug/L 101 MFL 1.8 _+10% 0.015 _+10% 0.009 mg/L _+10% 107to 108fibers/L _t 1.0 ug/L 1.0 ug/L 2 ug/L 0.17 MFL 1.0 ug/L 1.0 ug/L 2 ug/L 0.17 MFL 99.94 93.33 80.8 99.83 99.94 93.33 80.8 99.83 Live Cysts _ Turbidity Alachlor Endrin Ethylbenzene >99.95% 0.5 NTU 0.002 mg/L 0.002 mg/L 0.7 mg/L 120,000/L 11.4 NTU 41.3 ug/L 5.9 ug/L 1867 ug/L 50,000/L min. 11 _+1 NTU 0.04 _+10% 0.006 _+10% 2.1 _+10% 8/12 0.41 NTU 0.2 ug/L 0.5 ug/L 0.70 ug/L 1/L _ 0.24 NTU 0.2 ug/L 0.3 ug/L 0.0588 ug/L 99.99 96.4 99.52 91.5 99.96 >99.99 97.89 99.52 95.47 100 Lindane Chlorobenzene Tetrachloroethylene TTHM 0.002 mg/L 0.6 mg/L 0.005 mg/L 0.080 mg/L 1.9 ug/L 2.0 ug/L 14.2 ug/L 465 ug/L 0.002 _+10% 2.0 _+10% 0.015 _+10% 0.45 _+20% 0.02 ug/L 0.0005 ug/L 0.5 ug/L 1.0 ug/L 0.02 ug/L 0.0005 ug/L 0.5 ug/L 0.5 ug/L 98.93 99.98 96.47 99.78 98.93 99.98 96.47 99.88 MTBE VOC 0.005 mg/L 0.015 mg/L 14 ug/L 0.3520 mg/L 0.015 _+20% 0.300 _+10% 0.70 ug/L 0.0060 mg/L 0.52 ug/L 0.0008 mg/L 94.94 98.4 96.27 99.78 Test Parameters: pH = 7.5 + 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). • It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised. system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. • Refer to the front cover or "Accessories" section for the • Model T1KB1 : The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. Style 1 - When the filter indicator reads 10%, order a new filter. When the filter indicator reads 0%, it is recommended that you replace the filter. Style 2 - When the filter indicator light changes from green to yellow, order a new filter. When the filter indicator light changes from yellow to red, it is recommended that you replace the filter. Use replacement cartridge T1RFKB1, part #9030. In Canada, use replacement cartridge T1 RFKB1, part #9030B. 2008 suggested retail price of $41.99 U.S.A./S51.99 Canada. Prices are subject to change without notice. Manufacturer's name, address and telephone number. • Refer to the "Warranty" section for the Manufacturer's limited warranty. Application Guidelines/Water Supply Parameters Water Supply Water Pressure Water Temperature Service Flow Rate City or Well 30 - 120 psi (207 - 827 kPa) 33 ° - 100°F (0.6 ° - 37.8°C) 0.5 gpm (1.9 L/min) @ 60 psi • These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary. • The product is for cold water use only. • Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the *Class I particle size: >0.5 to

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

PERFORMANCE DATA SHEET
@
Base Grille Water
Filtration
System
Model
TIKB1/TIRFKB1
Capacity
100 Gallons
(379
Liters)
System
tested
and
certified
by NSF International
against
NSF/ANSI
Standard
42 for the
reduction
of
Chlorine
Taste and
Odor,
Particulate
Class
I*; and against
NSF/ANSl
Standard
53 for the reduction
of
Lead,
Mercury,
Atrazine,
Benzene,
Toxaphene,
O-Dichlorobenzene,
Cysts,
Turbidity,
Asbestos,
Lindane,
Tetrachloroethylene,
Endrin,
Alachlor,
Chlorobenzene,
Ethylbenzene,
TI-HM,
MTBE
and VOC.
This
system
has been
tested
according
to
NSF/ANSl
Standards
42 and
53 for the
reduction
of the substances
listed
below.
The
concentration
of the
indicated
substances
in water
entering
the system
was
reduced
to a concentration
less than
or equal
to the
permissible
limit
for water
leaving
the system,
as specified
in NSF/ANSl
Standards
42 and
53.
Substance
Reduction
NSF Reduction
Average
Influent
Challenge
Maximum
Average
Minimum
%
Average
%
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine
Taste/Odor
50% reduction
2.0 mg/L
2.0 mg/L
_+10%
0.08 mg/L
2.0 mg/L
95.93
97.36
Particulate
Class
I*
85% reduction
3533333#/mL
At
east 10,000
part c es/mL
22000 #/mL**
11567
#/mL
99.38
99.67
Contaminant
NSF Reduction
Average
Influent
Challenge
Maximum
Average
Minimum
%
Average
%
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.010 rng/L
150 ug/L
0.15 mg/L _+10%
1.0 ug/L
1 ug/L
99.33
99.33
Lead: @ pH 8.5
0.010 mg/L
157 ug/L
0.15 mg/L _+10%
2.0 ug/L
1.08 ug/L
98.72
99.31
Mercury:
@ pH 6.5
0.002 mg/L
0.0058
mg/L
0.006 mg/L
_+10%
0.0002
mg/L
0.0002
mg/L
96.53
96.53
Mercury:
@ pH 8.5
0.002 mg/L
0.0057
mg/L
0.006 mg/L
_+10%
0.0002
mg/L
0.0002
mg/L
96.5
96.5
Benzene
0.005 mg/L
15 ug/L
0.015 mg/L
_+10%
0.5 ug/L
0.5 ug/L
96.67
96.67
O-Dichlorobenzene
0.6 mg/L
1750 ug/L
1.8 _+10%
1.0 ug/L
1.0 ug/L
99.94
99.94
Toxaphene
0.003 mg/L
15 ug/L
0.015 _+10%
1.0 ug/L
1.0 ug/L
93.33
93.33
Atrazine
0.003 mg/L
10 ug/L
0.009 mg/L
_+10%
2 ug/L
2 ug/L
80.8
80.8
Asbestos
99%
101 MFL
107to 108fibers/L _t
0.17 MFL
0.17 MFL
99.83
99.83
Live Cysts _
>99.95%
120,000/L
50,000/L
min.
8/12
1/L _
99.99
>99.99
Turbidity
0.5 NTU
11.4 NTU
11 _+1 NTU
0.41 NTU
0.24 NTU
96.4
97.89
Alachlor
0.002 mg/L
41.3 ug/L
0.04 _+10%
0.2 ug/L
0.2 ug/L
99.52
99.52
Endrin
0.002 mg/L
5.9 ug/L
0.006 _+10%
0.5 ug/L
0.3 ug/L
91.5
95.47
Ethylbenzene
0.7 mg/L
1867 ug/L
2.1 _+10%
0.70 ug/L
0.0588
ug/L
99.96
100
Lindane
0.002 mg/L
1.9 ug/L
0.002 _+10%
0.02 ug/L
0.02 ug/L
98.93
98.93
Chlorobenzene
0.6 mg/L
2.0 ug/L
2.0 _+10%
0.0005
ug/L
0.0005
ug/L
99.98
99.98
Tetrachloroethylene
0.005 mg/L
14.2 ug/L
0.015 _+10%
0.5 ug/L
0.5 ug/L
96.47
96.47
TTHM
0.080 mg/L
465 ug/L
0.45 _+20%
1.0 ug/L
0.5 ug/L
99.78
99.88
MTBE
0.005 mg/L
14 ug/L
0.015 _+20%
0.70 ug/L
0.52 ug/L
94.94
96.27
VOC
0.015 mg/L
0.3520
mg/L
0.300 _+10%
0.0060
mg/L
0.0008
mg/L
98.4
99.78
Test
Parameters:
pH = 7.5 + 0.5 unless
otherwise
noted.
Temp.
= 68°F
to 71.6°F
(20°C to
22°C).
Flow
= 0.5 gpm
(1.9 Lpm).
Pressure
= 60 psig
(413.7
kPa).
It is essential
that
operational,
maintenance,
and
filter
replacement
requirements
be carried
out for the
product
to
perform
as advertised.
Model
T1KB1
: The filter
monitor
system
measures
the
amount
of
water
that
passes
through
the filter
and
alerts
you to
replace
the
filter.
Style
1 - When
the
filter
indicator
reads
10%,
order
a new filter.
When
the filter
indicator
reads
0%,
it is recommended
that
you
replace
the filter.
Style
2 - When
the
filter
indicator
light
changes
from green
to
yellow,
order
a new filter. When
the filter
indicator
light
changes
from yellow
to red, it is recommended
that you
replace
the filter.
Use replacement
cartridge
T1RFKB1,
part #9030.
In Canada,
use
replacement
cartridge
T1 RFKB1,
part #9030B.
2008
suggested
retail price
of $41.99
U.S.A./S51.99
Canada.
Prices
are subject
to
change
without
notice.
These
contaminants
are not necessarily
in your
water
supply.
While
testing
was
performed
under
standard
laboratory
conditions,
actual
performance
may
vary.
The
product
is for cold
water
use only.
Do not
use with
water
that
is microbiologically
unsafe
or of
unknown
quality
without
adequate
disinfection
before
or after the
system.
Systems
certified
for cyst
reduction
may be used
on
disinfected
waters
that
may contain
filterable
cysts.
Refer
to the
front
cover
or "Accessories"
section
for the
Manufacturer's
name,
address
and telephone
number.
Refer
to the
"Warranty"
section
for the
Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water
Supply
City
or Well
Water
Pressure
30 - 120 psi
(207 - 827
kPa)
Water
Temperature
33 ° - 100°F
(0.6 ° - 37.8°C)
Service
Flow
Rate
0.5
gpm
(1.9 L/min)
@ 60 psi
*Class
I particle
size: >0.5 to <1 um
**Test requirement
is at least
100,000
particles/mL
of AC Fine Test Dust.
t+Fibers greater than 10 um in length
_Based on the use of Cryptosporidium
parvum
oocysts
® NSF is a registered
trademark
of NSF International.
22