Kenmore 5814 Use and Care Guide - Page 22
Performance Data Sheet
UPC - 883049122533
View all Kenmore 5814 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
PERFORMANCE DATA SHEET @ Base Grille Water Filtration System Model TIKB1/TIRFKB1 Capacity 100 Gallons (379 Liters) System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSl Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos, Lindane, Tetrachloroethylene, Endrin, Alachlor, Chlorobenzene, Ethylbenzene, TI-HM, MTBE and VOC. This system has been tested according to NSF/ANSl Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSl Standards 42 and 53. Substance Reduction NSF Reduction Average Aesthetic Effects Requirements Influent Influent Challenge Concentration Maximum Effluent Average Effluent Minimum % Average % Reduction Reduction Chlorine Taste/Odor Particulate Class I* Contaminant Reduction Lead: @ pH 6.5 Lead: @ pH 8.5 Mercury: @ pH 6.5 Mercury: @ pH 8.5 Benzene 50% reduction 85% reduction NSF Reduction Requirements 0.010 rng/L 0.010 mg/L 0.002 mg/L 0.002 mg/L 0.005 mg/L 2.0 mg/L 3533333#/mL Average Influent 150 ug/L 157 ug/L 0.0058 mg/L 0.0057 mg/L 15 ug/L 2.0 mg/L _+10% At east 10,000 part c es/mL Influent Challenge Concentration 0.08 mg/L 22000 #/mL** Maximum Effluent 0.15 mg/L _+10% 0.15 mg/L _+10% 1.0 ug/L 2.0 ug/L 0.006 mg/L _+10% 0.006 mg/L _+10% 0.0002 mg/L 0.0002 mg/L 0.015 mg/L _+10% 0.5 ug/L 2.0 mg/L 11567 #/mL Average Effluent 1 ug/L 1.08 ug/L 0.0002 mg/L 0.0002 mg/L 0.5 ug/L 95.93 99.38 Minimum % Reduction 99.33 98.72 96.53 96.5 96.67 97.36 99.67 Average % Reduction 99.33 99.31 96.53 96.5 96.67 O-Dichlorobenzene Toxaphene Atrazine Asbestos 0.6 mg/L 0.003 mg/L 0.003 mg/L 99% 1750 ug/L 15 ug/L 10 ug/L 101 MFL 1.8 _+10% 0.015 _+10% 0.009 mg/L _+10% 107to 108fibers/L _t 1.0 ug/L 1.0 ug/L 2 ug/L 0.17 MFL 1.0 ug/L 1.0 ug/L 2 ug/L 0.17 MFL 99.94 93.33 80.8 99.83 99.94 93.33 80.8 99.83 Live Cysts _ Turbidity Alachlor Endrin Ethylbenzene >99.95% 0.5 NTU 0.002 mg/L 0.002 mg/L 0.7 mg/L 120,000/L 11.4 NTU 41.3 ug/L 5.9 ug/L 1867 ug/L 50,000/L min. 11 _+1 NTU 0.04 _+10% 0.006 _+10% 2.1 _+10% 8/12 0.41 NTU 0.2 ug/L 0.5 ug/L 0.70 ug/L 1/L _ 0.24 NTU 0.2 ug/L 0.3 ug/L 0.0588 ug/L 99.99 96.4 99.52 91.5 99.96 >99.99 97.89 99.52 95.47 100 Lindane Chlorobenzene Tetrachloroethylene TTHM 0.002 mg/L 0.6 mg/L 0.005 mg/L 0.080 mg/L 1.9 ug/L 2.0 ug/L 14.2 ug/L 465 ug/L 0.002 _+10% 2.0 _+10% 0.015 _+10% 0.45 _+20% 0.02 ug/L 0.0005 ug/L 0.5 ug/L 1.0 ug/L 0.02 ug/L 0.0005 ug/L 0.5 ug/L 0.5 ug/L 98.93 99.98 96.47 99.78 98.93 99.98 96.47 99.88 MTBE VOC 0.005 mg/L 0.015 mg/L 14 ug/L 0.3520 mg/L 0.015 _+20% 0.300 _+10% 0.70 ug/L 0.0060 mg/L 0.52 ug/L 0.0008 mg/L 94.94 98.4 96.27 99.78 Test Parameters: pH = 7.5 + 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). • It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised. system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. • Refer to the front cover or "Accessories" section for the • Model T1KB1 : The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. Style 1 - When the filter indicator reads 10%, order a new filter. When the filter indicator reads 0%, it is recommended that you replace the filter. Style 2 - When the filter indicator light changes from green to yellow, order a new filter. When the filter indicator light changes from yellow to red, it is recommended that you replace the filter. Use replacement cartridge T1RFKB1, part #9030. In Canada, use replacement cartridge T1 RFKB1, part #9030B. 2008 suggested retail price of $41.99 U.S.A./S51.99 Canada. Prices are subject to change without notice. Manufacturer's name, address and telephone number. • Refer to the "Warranty" section for the Manufacturer's limited warranty. Application Guidelines/Water Supply Parameters Water Supply Water Pressure Water Temperature Service Flow Rate City or Well 30 - 120 psi (207 - 827 kPa) 33 ° - 100°F (0.6 ° - 37.8°C) 0.5 gpm (1.9 L/min) @ 60 psi • These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary. • The product is for cold water use only. • Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the *Class I particle size: >0.5 to