Konica Minolta bizhub PRESS 1250 Watkiss PowerSquare 224 User Manual - Page 52
Open the PSQ main deck. See Lift the PowerSquare Main Deck on See Install New
View all Konica Minolta bizhub PRESS 1250 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
5 - Error Conditions, Problems and Solutions - Book Quality Problems Is the number of STITCHES set between 1 and 6? Yes No Select STITCHES 1 - 6. See "STITCHES" on page 18. Check the stitch-wire spool. Is there stitch-wire present? Yes No Load a new stitch-wire spool. See "Install New Stitch-wire" on page 94. Open the PSQ main deck. See "Lift the PowerSquare Main Deck" on page 31. Pull approximately 100-150mm of stitch-wire from the stitch wire spool. See Figure 24 on p.47. Does the wire move freely? Yes No Open the stitch-wire cabinet. Discard any tangled wire and reload the stitch-wire spool. See "Install New Stitch-wire" on page 94. Check the stitch head for stitch-wire jams. See Figure 25 on p.47. Is the stitch head clear of stitch-wire jams? Yes No Clear the stitch-wire jam. See "Clear a Stitch-wire Jam" on page 72. Lubricate the stitch head. See "Lubricate the Stitch Head" on page 89. Does the problem continue? Yes No Further action is not needed. Call your service engineer 48 Watkiss PowerSquare™224 User Manual