Konica Minolta bizhub PRESS C71hc bizhub PRESS C1070/C1070P/C1060/C71hc/bizhub - Page 93

Specifying the reference image quality, bizhub PRESS C1070/C1070P/C1060/C71hc

Page 93 highlights

bizhub PRESS C1070/C1070P/C1060/C71hc bizhub PRO C1060L Specifying the reference image quality To stabilize the image quality of this machine, specify the reference values (targets) of the entire printing system in advance. If you change the setting value in [Custom Screen], hue variations may be drastically changed. If you change the screen, specify the standard image quality following the procedure to avoid hue variations. Tips If the image quality has not been appropriately adjusted only through daily calibration, you may improve the situation by carrying out the following tasks. Order STEP1 STEP2 STEP3 STEP4 Menu item Without Relay Unit With Relay Unit RU- RU-509 509 Screen Pattern (Refer to the HTML User's Guide.) Gamma Automatic Adj. (Refer to the HTML User's Guide.) Density Balance Adjustment (Refer to the HTML User's Guide.) Calibration (page 5-36) [Color Density Control] (page 5-31) Description Select the screen to be used with the screen setting (assignment) changed. Automatically adjusts the color reproducibility of all the output paper. Automatically corrects the density balance. Calibration: Calibrates the color reproducibility that fluctuates from day to day. STEP5 Color Balance Adjustment (Refer to the HTML User's Guide.) [Color Density Control]: Select [Basic Setting], then set [Periodical Adj. Execution] to [ON]. If necessary, execute [Color Density Manual Control]. Execute Exact Color or the G7 calibration to enhance the color balance reproducibility. Carry out the adjustment continuously in sequence. If you have interrupted the adjustment, select "Step 2. Gamma Automatic Adj." each time before restarting calibration. For example, if the adjustment is interrupted at the end of "Step 3. Density Balance Adjustment", execute "Step 2. Gamma Automatic Adj." at the time of restart, then execute "Step 4. Calibration (without Relay Unit RU-509)" or "Step 4. Color Density Control (with Relay Unit RU-509 installed)" in sequence. If sufficient adjustment results are not obtained via daily maintenance, also carry out the adjustment in this order. For details about the setting procedure, refer to the HTML User's Guide. 5 5-43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155

5-43
bizhub PRO C1060L
5
bizhub PRESS C1070/C1070P/C1060/C71hc
Specifying the reference image quality
To stabilize the image quality of this machine, specify the reference values (targets) of the entire printing system in
advance.
If you change the setting value in [Custom Screen], hue variations may be drastically changed. If you change the
screen, specify the standard image quality following the procedure to avoid hue variations.
Tips
If the image quality has not been appropriately adjusted only through daily calibration, you may improve the situation
by carrying out the following tasks.
Carry out the adjustment continuously in sequence. If you have interrupted the adjustment, select "Step 2. Gamma
Automatic Adj." each time before restarting calibration. For example, if the adjustment is interrupted at the end of "Step
3. Density Balance Adjustment", execute "Step 2. Gamma Automatic Adj." at the time of restart, then execute "Step
4. Calibration (without
Relay Unit RU-509
)" or "Step 4. Color Density Control (with
Relay Unit RU-509
installed)" in
sequence.
If sufficient adjustment results are not obtained via daily maintenance, also carry out the adjustment in this order.
For details about the setting procedure, refer to the
HTML User's Guide
.
Order
Menu item
Description
Without Relay Unit
RU-509
With Relay Unit RU-
509
STEP1
Screen Pattern (Refer to the
HTML User's
Guide
.)
Select the screen to be used with the screen set-
ting (assignment) changed.
STEP2
Gamma Automatic Adj. (Refer to the
HTML
User's Guide
.)
Automatically adjusts the color reproducibility of
all the output paper.
STEP3
Density Balance Adjustment (Refer to the
HTML User's Guide
.)
Automatically corrects the density balance.
STEP4
Calibration
(page 5-36)
[Color Density Con-
trol] (page 5-31)
Calibration:
Calibrates the color reproducibility that fluctuates
from day to day.
[Color Density Control]:
Select [Basic Setting], then set [Periodical Adj.
Execution] to [ON]. If necessary, execute [Color
Density Manual Control].
STEP5
Color Balance Adjustment (Refer to the
HTML
User's Guide
.)
Execute Exact Color or the G7 calibration to en-
hance the color balance reproducibility.