Lenovo ThinkPad 380ED HMM ThinkPad 380XD,385XD (May 1998) - Page 46

Symptom-to-FRU Index, Numeric Error Codes, any number.

Page 46 highlights

Symptom-to-FRU Index The Symptom-to-FRU Index lists the symptoms and errors and the possible causes. The most likely cause is listed first. Note: Perform the FRU replacement or actions in the sequence shown in the "FRU/Action" columns. If a FRU replacement did not solve the problem, put the original part back in the computer. Do not replace a nondefective FRU. This index can also help you determine the next possible FRUs to be replaced when servicing a computer. Numeric error codes show the errors detected in POST or system operation. In the following error codes, X can be any number. If no codes are available, use narrative symptoms. If the symptom is not listed, go to "Undetermined Problems" on page 48. Note: For IBM devices not supported by diagnostic codes in the ThinkPad notebook computers, see the manual for that device. Numeric Error Codes Symptom / Error 10X 101: Interrupt failure. 102: Timer failure. 103: Timer interrupt failure. 104: Protected mode failure. 105: Last 8042 command not accepted. 107: NMI test failure. 108: Timer bus test failure. 109: Low meg-chip select test. 110 (Planar parity.) FRU / Action in Sequence System board 1. Go to "Memory Checkout" on page 28. 2. DIMM 3. Detach the expansion unit if it is attached to the computer. 4. System board 38 IBM ThinkPad 380XD, 385XD

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132

Symptom-to-FRU Index
The Symptom-to-FRU Index lists the symptoms and errors
and the possible causes.
The most likely cause is listed
first.
Note:
Perform the FRU replacement or actions in the
sequence shown in the “FRU/Action” columns.
If a
FRU replacement did not solve the problem, put
the original part back in the computer.
Do not
replace a nondefective FRU.
This index can also help you determine the next possible
FRUs to be replaced when servicing a computer.
Numeric error codes show the errors detected in POST or
system operation.
In the following error codes,
X
can be
any number.
If no codes are available, use narrative symptoms.
If the symptom is not listed, go to “Undetermined
Problems” on page
48.
Note:
For IBM devices not supported by diagnostic
codes in the ThinkPad notebook computers,
see the manual for that device.
Numeric Error Codes
Symptom / Error
FRU / Action in Sequence
10X
101: Interrupt failure.
102: Timer failure.
103: Timer interrupt
failure.
104: Protected mode
failure.
105: Last 8042
command not
accepted.
107:
NMI test failure.
108:
Timer bus test
failure.
109: Low meg-chip
select test.
System board
110
(Planar parity.)
1.
Go to “Memory
Checkout” on
page 28.
2.
DIMM
3.
Detach the expansion
unit if it is attached to
the computer.
4.
System board
38
IBM ThinkPad 380XD, 385XD