Min=2.25 x Bar Width 1 and, Max=3 x Bar Width 1.
View all Lexmark X925 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 89 highlights
ITF-14 Key /Symbology Type name /Units name /Height int /Bars [int int] /Spaces [int int] Range n/a /300ths /600ths /1200ths Minimum: 307 (dec) 01 33 (hex) Maximum: There is no maximum value, but larger bar codes use up more memory. Minimum: [12 27] (dec) Maximum: [24 72] (dec) Minimum: [12 27] (dec) Maximum: [24 72] (dec) Default value n/a /600ths 756 (dec) 02 F4 (hex) [12] (dec) [00 0C] (hex) Space Width 1: 12 (dec) 00 0C (hex) Description Required Identifies the bar code symbology (/ITF14) Optional /Units is used in the calculations below Optional Sets the bar height in /Units Notes: • Bar height does not include the bearer bars. • Values beyond the defined range are appropriately clipped and set to the minimum and maximum values. Optional Sets the bar widts in /Units Notes: • The default value for Bar Width 2 is dependent on the value of Bar Width 1, where Default=2.50 x Bar Width 1. • The range of values for Bar Width 2 is dependent on the value of Bar Width 1, where, Min=2.25 x Bar Width 1 and Max=3 x Bar Width 1. • Values beyond the defined range are appropriately clipped and set to the minimum and maximum values. Optional Sets the space widths in /Units Notes: • The range of values for Space Width 2 is dependent on the value of Space Width 1, where Min=2.25 x Space Width 1 Max=3 x Space Width 1. • Values beyond the defined range are appropriately clipped and set to the minimum and maximum values. Two-dimensional bar codes 86