Lexmark XS748 Printer Languages and Interfaces Technical Reference - Page 99

Memory VM., statusdict, startjob

Page 99 highlights

PostScript emulation 99 Key Type MaxDisplayList integer MaxDisplayAndSource List MaxFontCache MaxFormCache integer MaxImageBuffer MaxOutlineCache MaxPatternCache integer integer MaxPermanentVM MaxRasterMemory MaxScreenStorage MaxSourceList MaxUPathCache integer integer PageCount PanelCode PrinterCode PrinterName integer string string string RamSize RealFormat integer string Revision integer SearchBuiltinFontsFirst Boolean SerialNumber string StartJobPassword string Definition (Read‑only) Always have the same value as InstalledRam. Maximum bytes occupied by the form cache. Legal value: Any non‑negative integer. (Read‑only) Always have the same value as InstalledRam. Maximum bytes occupied by the pattern cache. Legal value: Any non‑negative integer. (Read‑only) Always have the same value as InstalledRam. Maximum bytes occupied by the user path cache. Legal value: Any non‑negative integer. (Read‑only) Total number of pages that have been printed. (Read‑only) Version of the control panel code. (Read‑only) Firmware version of the printer controller board. Initialized from the printer name stored in NVRAM. If this parameter is set to a zero length string, then the PrinterName is set to the value of the product string in statusdict. Legal value: Any string of 32 or fewer non‑null characters. (Read‑only) Total amount of memory in bytes installed in the printer. (Read‑only) Preferred representation for real numbers in binary encoded tokens. (Read‑only) The current revision level of the machine‑dependent portion of PostScript emulation. Controls the device search order that the interpreter uses to locate fonts. (Read‑only) Serial number of the printer. (Write‑only) Controls the ability of the startjob operator to alter initial Virtual Memory (VM). Legal values: Any integer or string of 32 or fewer non‑null characters. An integer is converted to a string.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

Key
Type
Definition
MaxDisplayList
integer
(Read
only) Always have the same value as InstalledRam.
MaxDisplayAndSource
List
MaxFontCache
MaxFormCache
integer
Maximum bytes occupied by the form cache.
Legal value: Any non
negative integer.
MaxImageBuffer
integer
(Read
only) Always have the same value as InstalledRam.
MaxOutlineCache
MaxPatternCache
integer
Maximum bytes occupied by the pattern cache.
Legal value: Any non
negative integer.
MaxPermanentVM
integer
(Read
only) Always have the same value as InstalledRam.
MaxRasterMemory
MaxScreenStorage
MaxSourceList
MaxUPathCache
integer
Maximum bytes occupied by the user path cache.
Legal value: Any non
negative integer.
PageCount
integer
(Read
only) Total number of pages that have been printed.
PanelCode
string
(Read
only) Version of the control panel code.
PrinterCode
string
(Read
only) Firmware version of the printer controller board.
PrinterName
string
Initialized from the printer name stored in NVRAM. If this parameter is set
to a zero length string, then the PrinterName is set to the value of the
product string in
statusdict
.
Legal value: Any string of 32 or fewer non
null characters.
RamSize
integer
(Read
only) Total amount of memory in bytes installed in the printer.
RealFormat
string
(Read
only) Preferred representation for real numbers in binary encoded
tokens.
Revision
integer
(Read
only) The current revision level of the machine
dependent portion of
PostScript emulation.
SearchBuiltinFontsFirst
Boolean
Controls the device search order that the interpreter uses to locate fonts.
SerialNumber
string
(Read
only) Serial number of the printer.
StartJobPassword
string
(Write
only) Controls the ability of the
startjob
operator to alter initial Virtual
Memory (VM).
Legal values: Any integer or string of 32 or fewer non
null characters. An
integer is converted to a string.
PostScript emulation
99