LiftMaster HDSW24UL Installation Manual - English - Page 30
Erase All Codes, Erase Limits, Constant Pressure Override (CPO), Gate Hold Open Feature
View all LiftMaster HDSW24UL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
PROGRAMMING 6. Validate - Validate functionality by selecting Test Relay on the CAPXL display. For more information refer to the CAPXL documentation. myQ® Business™: To find out more on how to simply secure all of your access points with an easy to manage integrated system, myQ Business, please visit: www.myqbusiness.com. Constant Pressure Override (CPO) Constant Pressure Override is for use with KPW5 and KPW250 keypads (not provided). The KPW5/KPW250 wireless commercial keypads are security keypads and can only be programmed to ONE gate operator (see the KPW5/KPW250 manual for complete programming instructions). The Constant Pressure Override feature is intended to temporarily override a fault in the entrapment protection system, in order to operate the gate until the external entrapment protection device is realigned or repaired. Use the feature only in line of sight of the gate when no obstructions to travel are present. External entrapment protection devices include LiftMaster monitored photoelectric sensors and LiftMaster monitored wired and wireless edge sensors. Be sure to repair or replace these devices promptly if they are not working properly. To use Constant Pressure Override: 1. Enter a valid 4-digit PIN. 2. Press and hold # for 5 seconds to enter CPO. Continue to hold # to keep the operator in motion. A continuous tone will sound until limit is met and/or # is released. 3. The operator will stop when either the operator reaches a limit or the user releases #. Erase All Codes 1. Press and release the LEARN button (operator will beep and green XMITTER LED will light). 2. Press and hold the LEARN button again until the green XMITTER LED flashes and then release the button (approximately 6 seconds). All remote control codes are now erased. Erase Limits 1. To erase the limits, press and hold the SET OPEN and SET CLOSE buttons simultaneously (5 seconds) until both the SET OPEN and SET CLOSE LEDs blink rapidly and the operator beeps. 2. Release the buttons and the SET OPEN and SET CLOSE LEDs will blink slowly indicating the limits will need to be set. Gate Hold Open Feature The gate hold open feature will disable the timer and keep the gate at the open limit. The gate hold open feature can be activated with the reset switch, see page 33 or on the KPW5 and KPW250 keypads (not provided). To use the gate hold open feature on a keypad: 1. Enter a valid 4-digit PIN when the gate is at the open limit and the timer is running 2. The operator will chirp indicating the timer is canceled. To restart the gate: 1. Re-enter the 4-digit PIN 2. Activate a hard input or a programmed remote To Remove and Erase Monitored Entrapment Protection Devices 1. Remove the entrapment protection device wires from the terminal block. 2. Press and release the SET OPEN and SET CLOSE buttons simultaneously. The SET OPEN and SET CLOSE LEDs will turn on (entering learn limit mode). 3. Press and release both SET OPEN and SET CLOSE buttons again to turn off the SET OPEN and SET CLOSE LEDs (exiting learn limit mode). 30