Timeout Between Decodes, Same Symbol, Different Symbol
View all Motorola LS2208-SR20007R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
User Preferences 4 - 9 Timeout Between Decodes Timeout Between Decodes, Same Symbol This parameter sets the minimum time between decodes of the same symbol. It is programmable in 0.1-second increments from 0.0 to 9.9 seconds. Setting this above 0.4 seconds is recommended. The default for this parameter is 0.6 seconds. Scan the bar code below to select a new timeout. Next, scan two numeric bar codes beginning in Numeric Bar Codes on page D-1 that correspond to the desired timeout. Include a leading zero for single digit numbers. For example, to set a timeout of 0.5 seconds, scan the bar code below, then scan the "0" and "5" bar codes. If an error occurs, or to change the selection, scan Cancel on page D-3. Timeout Between Same Symbol Timeout Between Decodes, Different Symbol This parameter sets the minimum time between decodes of different symbols. It is programmable in 0.1-second increments from 0.0 to 9.9 seconds. The default for this parameter is 0.2 seconds. Scan the bar code below to select a new timeout. Next, scan two numeric bar codes beginning in Numeric Bar Codes on page D-1 that correspond to the desired timeout. Include a leading zero for single digit numbers. For example, to set a timeout of 0.5 seconds, scan the bar code below, then scan the "0" and "5" bar codes. If an error occurs, or to change the selection, scan Cancel on page D-3. Timeout Between Different Symbol