Page 1 highlights
External Control LCD4010 / LCD4610 1. Application This document defines the communications method for control of the LCD4010/LCD4610 when using an external controller. 2. Connectors and wiring Connector: D-Sub 9-pin Cable: Cross (reversed) cable or null modem cable 3. Communication Parameter (1) Communication system Asynchronous (2) Interface RS-232C (3) Baud rate 9600bps (4) Data length (5) Parity (6) Stop bit 8bits None 1 bit (7) Communication code ASCII 3.1 Communication timing The controller should wait for a packet interval before next command is sent. The packet interval needs to be longer than 600msec for the LCD4010/LCD4610. (1/37)
(1/37)
External Control
LCD4010 / LCD4610
1. Application
This document defines the communications method for control of the LCD4010/LCD4610 when using an
external controller
.
2. Connectors and wiring
Connector: D-Sub 9-pin
Cable: Cross (reversed) cable or null modem cable
3. Communication Parameter
(1) Communication system Asynchronous
(2) Interface
RS-232C
(3) Baud rate
9600bps
(4) Data length
8bits
(5) Parity
None
(6) Stop bit
1 bit
(7) Communication code ASCII
3.1 Communication timing
The controller should wait for a packet interval before next command is sent.
The packet interval needs to be longer than 600msec for the LCD4010/LCD4610.