NEC LCD4010-BK LCD4010 external control command - Page 20
Date & Time Write
UPC - 805736012224
View all NEC LCD4010-BK manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
'1'-'F'(31h, 46h): 31(=1Fh) WW: weekdays '0'-'0'(30h, 30h): Sunday '0'-'1'(30h, 31h): Monday '0'-'2'(30h, 32h): Tuesday '0'-'3'(30h, 33h): Wednesday '0'-'4'(30h, 34h): Thursday '0'-'5'(30h, 35h): Friday '0'-'6'(30h, 36h): Saturday HH: Hours '0'-'0'(30h, 30h): 0 | '1'-'7'(31h, 37h): 23 (=17h) MN: Minutes '0'-'0'(30h, 30h): 0 | '3'-'B' (33h, 42h): 59 (=3Bh) DS: Daylight saving (Summer time) '0'-'0'(30h, 30h): NO '0'-'1'(30hm 31h): YES ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet 9.2 Date & Time Write This command is used in order to write the setting of the Date & Time. 1) The controller requests the monitor to write Date & Time. Header SOH-'0'-Monitor ID-'0'-'A'-'1'-'2' Message STX-'C'-'2'-'1'-'2'-YY-MM-DD-WW-HH-MN -DS-ETX Check code BCC Delimiter CR Header SOH (01h): Start Of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change the setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller 'A' (41h): Message type is "Command" '1'-'2'(31h, 32h): Message length. Message STX (02h): Start of Message 'C'-'2'-'1'-'2' (43h, 32h, 31h, 32h): Date & Time write command 'YY'-'MM'-'DD'-'WW'-'HH'-'MN'-'DS': Date & Time data YY: Year (offset 2000) '0'-'0'(30h, 30h): 2000 | '6'-'3'(36h, 33h): 2099 (99 = 63h) MM: Month '0'-'1'(30h, 31h): January | '0'-'C'(30h, 43h): December DD: Day '0'-'1'(30h, 31h): 1 (20/37)