NEC LCD4010-BK LCD4010 external control command - Page 17

Asset Data read and write

Page 17 highlights

Delimiter CR (0Dh): End of packet. 8. Asset Data read and write 8.1 Asset Data Read Request and reply This command is used in order to read Asset Data. 1) The controller requests the monitor to reply with Asset data. Header SOH-'0'-Monitor ID-'0'-'A'-'0'-'A' Message STX-'C'-'0'-'0'-'B'-'0'-'0'-'2'-'0'-ETX Check code BCC Delimiter CR Header SOH (01h): Start Of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID from which you want to get data. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller 'A' (41h): Message type is "Command" '0'-'A' (30h, 41h): Message length is 10 bytes Message STX (02h): Start of Message 'C'-'0'-'0'-'B' (43h, 30h, 30, 42h): Asset read request command '0'-'0' (30h, 30h): Offset data from top of the Asset data. At first set 00h: Read data from the top of Asset data area. Secondly set 20h: Read data from the 32bytes offset point in the Asset data area. '2'-'0' (32h, 30h): Read out data length is 32bytes. Maximum readout length is 32bytes at a time. ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet 2) The monitor replies Asset data to the controller. Header SOH-'0'-'0'-Monitor ID-'B'-N-N Message STX-'C'-'1'-'0'-'B'Data(0)-Data(1)---Data(N)-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved '0' (30h): Message receiver is the controller Monitor ID: Indicate a replying Monitor ID Ex.) When this byte is set to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command reply" N-N: Message length Ex.) The byte data 20h is encoded to ASCII characters '2' and '0' (32h and 30h). Note.) This length is includes STX and ETX. Message STX (02h): Start of Message 'C'-'1'-'0'-'B' (43h, 31h, 30, 42h): Asset read reply command Data(0) - Data(N): Retuned Asset data. ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. Delimiter (17/37)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37

(17/37)
Delimiter
CR (0Dh): End of packet.
8. Asset Data read and write
8.1 Asset Data Read Request and reply
This command is used in order to read Asset Data.
1) The controller requests the monitor to reply with Asset data.
Header
Message
Check code
Delimiter
SOH-'0'-Monitor ID-'0'-'A'-'0'-'A'
STX-'C'-'0'-'0'-'B'-'0'-'0'-'2'-'0'-ETX
BCC
CR
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID from which you want to get data.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller
'A' (41h): Message type is "Command"
'0'-'A' (30h, 41h): Message length is 10 bytes
Message
STX (02h): Start of Message
'C'-'0'-'0'-'B'
(43h, 30h, 30, 42h): Asset read request command
'0'-'0' (30h, 30h): Offset data from top of the Asset data.
At first set 00h: Read data from the top of Asset data area.
Secondly set 20h: Read data from the 32bytes offset point in the Asset data area.
'2'-'0' (32h, 30h): Read out data length is 32bytes.
Maximum readout length is 32bytes at a time.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Asset data to the controller.
Header
Message
Check code
Delimiter
SOH-'0'-'0'-Monitor ID-'B'-N-N
STX-'C'-'1'-'0'-'B'-
Data(0)-Data(1)---Data(N)-ETX
BCC
CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller
Monitor ID: Indicate a replying Monitor ID
Ex.)
When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply"
N-N: Message length
Ex.) The byte data 20h is encoded to ASCII characters '2' and '0' (32h and 30h).
Note.) This length is includes STX and ETX.
Message
STX (02h): Start of Message
'C'-'1'-'0'-'B'
(43h, 31h, 30, 42h): Asset read reply command
Data(0) – Data(N): Retuned Asset data.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter