NEC LCD4010-BK LCD4010 external control command - Page 26

PG-ON HOURS-ON MIN-OFF HOURS-OFF Min-NPUT-WD-FL: Schedule data

Page 26 highlights

Delimiter CR (0Dh): End of packet 2) The monitor replies a data for confirmation. Header Message SOH-'0'-'0'-Monitor ID-'B'-'1'-'8' STX-'C'-'3'-'1'-'4'-ST-PG-ON HOURS-ON MIN-OFF HOURS-OFF Min-NPUT-WD-FL-ETX Check code BCC Delimiter CR Header SOH (01h): Start Of Header '0' (30h): Reserved '0' (30h): Message receiver is the controller Monitor ID: Indicate a replying Monitor ID. Ex.) When this byte is set to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command reply" '1'-'8'(31h, 38h): Message length. Message STX (02h): Start of Message 'C'-'3'-'1'-'4' (43h, 33h, 31h, 34h): Schedule writes reply command ST: Schedule Status command 0(30h):No error 1(31h):Error PG-ON HOURS-ON MIN-OFF HOURS-OFF Min-NPUT-WD-FL: Schedule data PG: Program No. '0'-'0'(30h, 30h): Program No.1 | '0'-'6'(30h, 36h): Program No.7 ON_HOUR: Turn on time (hour) '0'-'0'(30h, 30h): 00 | '1'-'7'(31h, 37h): 23 (=17h) '1'-'8'(31h, 38h): ON timer isn't set. ON_MIN: Turn on time (minute) '0'-'0'(30h, 30h): 0 | '3'-'B'(33h, 42h): 59 '3'-'C'(33h, 43h): On timer isn't set. OFF_HOUR: Turn off time (hour) '0'-'0'(30h, 30h): 00 | '1'-'7'(31h, 37h): 23 (=17h) '1'-'8'(31h, 38h): Off timer isn't set. OFF_MIN: Turn off time (minute) '0'-'0'(30h, 30h): 0 | '3'-'B'(33h, 42h): 59 (=3Bh) '3'-'C'(33h, 43h): Off timer isn't set. INPUT: Timer input '0'-'0'(30h, 30h): RGB1(DVI-D) '0'-'1'(30h, 31h): RGB2(D-SUB) '0'-'2'(30h, 32h): RGB3(BNC) '0'-'3'(30h, 33h): DVD/HD '0'-'4'(30h, 34h): VIDEO '0'-'5'(30h, 35h): VIDEO(S) '0'-'7'(30h, 37h): It is operates by last memory input WD: Week setting bit 0: Monday bit 1: Tuesday bit 2: Wednesday bit 3: Thursday bit 4: Friday (26/37)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37

(26/37)
Delimiter
CR (0Dh): End of packet
2) The monitor replies a data for confirmation.
Header
Message
Check code
Delimiter
SOH-'0'-'0'-Monitor ID-'B'-'1'-'8' STX-'C'-'3'-'1'-'4'-ST-PG-ON HOURS-ON
MIN-OFF HOURS-OFF Min-NPUT-WD-FL-ETX
BCC
CR
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller
Monitor ID: Indicate a replying Monitor ID.
Ex.)
When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply"
'1'-'8'(31h, 38h): Message length.
Message
STX (02h): Start of Message
'C'-'3'-'1'-'4'
(43h, 33h, 31h, 34h): Schedule writes reply command
ST: Schedule Status command
0(30h):No error
1(31h):Error
PG-ON HOURS-ON MIN-OFF HOURS-OFF Min-NPUT-WD-FL: Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
ON_HOUR: Turn on time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): ON timer isn't set.
ON_MIN:
Turn on time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59
'3'-'C'(33h, 43h): On timer isn’t set.
OFF_HOUR: Turn off time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): Off timer isn't set.
OFF_MIN:
Turn off time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59 (=3Bh)
'3'-'C'(33h, 43h): Off timer isn’t set.
INPUT: Timer input
'0'-'0'(30h, 30h): RGB1(DVI-D)
'0'-'1'(30h, 31h): RGB2(D-SUB)
'0'-'2'(30h, 32h): RGB3(BNC)
'0'-'3'(30h, 33h): DVD/HD
'0'-'4'(30h, 34h): VIDEO
'0'-'5'(30h, 35h): VIDEO(S)
'0'-'7'(30h, 37h): It is o
perates by last memory input
WD: Week setting
bit 0: Monday
bit 1: Tuesday
bit 2: Wednesday
bit 3: Thursday
bit 4: Friday