Netgear WFS709TP WFS709TP Hardware manual - Page 24
Mounting the Chassis
UPC - 606449052336
View all Netgear WFS709TP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
WFS709TP ProSafe Smart Wireless Switch Hardware Installation Guide For best operation, keep the WFS709TP and all cords and cables at least 0.7 meters (2 feet) from fluorescent lighting fixtures, and 2 meters (6 feet) from photocopiers, radio transmitters, electric generators, and other sources of strong electromagnetic interference. See also Appendix B, "Specifications". Mounting the Chassis This section provides instructions for installing the WFS709TP ProSafe Smart Wireless Switch. 1. Make sure that your rack environment meets the installation requirements listed on page 2-3). 2. Attach the WFS709TP to the rack, as described in the following section Warning: To avoid personal injury or damage to equipment, get help in lifting and positioning the WFS709TP. Also, do not install the WFS709TP where instability or uneven mechanical loading may occur. Note: For proper operation, make sure your rack environment is in compliance with the operating temperatures described in Appendix B, "Specifications". • Position the chassis in the equipment rack and align the brackets' mounting holes with the corresponding holes in your rack frame (Figure 2-1 on page 2-5). 2-4 Installing the Chassis v1.0, May 2007