Auto Exposure Lock
UPC - 018208017775
View all Nikon 1776 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
Auto Exposure Lock • When you want to control the exposure of a specific area within a scene, measure the exposure on the area with Spot or Center-Weighted Metering, press the " button to lock the exposure, then recompose the picture. Set exposure to a mode other than Manual. 1 Rotate the metering system selector to select CenterWeighted or Spot Metering. • Matrix Metering is not recommended since the effect of the Auto Exposure Lock cannot be effectively attained. 2 Position focus area on subject and lightly press the shutter release button, then press the" button. Confirm focus indicator. appears in the viewfinder. • When the. button is pressed , exposure at the area of selected metering system is locked and remai ns locked as long as the button is kept pressed. • When the. button is pressed , EL appears in the viewfinder. • Area of exposure in Spot Metering: 1. When the focus area and metering area are linked in Spot Metering (page 49). exposure is locked at selected focus area. 2. When Dynamic AF Mode with Closest Subject Priority (page 40) is selected in Spot Metering , exposure is locked at center focus area (page 49) . 58