Sanyo PLC-XK2600 RS232 Expand - Page 51

CR_COLTEMP Command, 4.12 CR_NZRED Command, 4.13 CR_PROGV Command, 4.14 CR_IMAGE Command

Page 51 highlights

PLC-XK2200 /2600 /XK3010 Expand Serial Command Functional Specifications 9.4.11 CR_COLTEMP Command Command "CR_COLTEMP"[CR] Details Get Color Temp. setting value Acceptable "000_%a"[CR] "000 Xlow "001 Low "002 Mid Response %a "003 High "BLACK Blackboard(Green) mode selected "COLOR Colorboard selected "BLANK White Balance has been changed Unacceptable "Error Code"[CR] 9.4.12 CR_NZRED Command Command "CR_NZRED"[CR] Details Get setting status of Noise Reduction Acceptable "000_%1"[CR] "L1" -------- Noise Reduction for moving image Response %1 "L2" -------- Noise Reduction for still image "OFF" ----- Noise Reduction is OFF Unacceptable "Error Code"[CR] 9.4.13 CR_PROGV Command Command "CR_PROGV"[CR] Details Get setting status of Progressive scan Acceptable "000_%a"[CR] "L1 Progressive Mode L1 is selected Response %a "L2 Progressive Mode L2 is selected "FILM Progressive Model FILM is selected "OFF Progressive scan is disabled Unacceptable "Error Code"[CR] 9.4.14 CR_IMAGE Command Command "CR_IMAGE"[CR] Details Get image setting status Required data "CUSTOM1" to "CUSTOM4" is the same as "Image1" to "Image4" displayed when selecting IMAGE on OSD menu Acceptable "000_%a"[CR] "DYNAMIC Dynamic "STAND Standard "REAL Real Response %a "CINEMA Cinema "BLACKBOARD Blackboard "COLORBOARD Colorboard "CUSTOM1"~"CUSTOM4 Image1~4 Unacceptable "Error Code"[CR] ---- When the command is invalid due to condition such as Input source 51 / 73

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

PLC-XK2200 /2600 /XK3010
Expand Serial Command Functional Specifications
51 /
73
9.4.11 CR_COLTEMP Command
Command
"CR_COLTEMP”[CR]
Details
Get Color Temp. setting value
Acceptable
“000_%a”[CR]
%a
“000” ------------------------------ Xlow
“001” ------------------------------ Low
“002” ------------------------------ Mid
“003” ------------------------------ High
“BLACK” -------------------- Blackboard(Green) mode selected
“COLOR” ------------------- Colorboard selected
“BLANK” -------------------- White Balance has been changed
Response
Unacceptable
“Error Code”[CR]
9.4.12 CR_NZRED Command
Command
“CR_NZRED”[CR]
Details
Get setting status of Noise Reduction
Acceptable
“000_%1”[CR]
%1
“L1” -------- Noise Reduction for moving image
“L2” -------- Noise Reduction for still image
“OFF” ----- Noise Reduction is OFF
Response
Unacceptable
“Error Code”[CR]
9.4.13 CR_PROGV Command
Command
“CR_PROGV”[CR]
Details
Get setting status of Progressive scan
Acceptable
“000_%a”[CR]
%a
“L1” ----------------- Progressive Mode L1 is selected
“L2” ----------------- Progressive Mode L2 is selected
“FILM” -------------- Progressive Model FILM is selected
“OFF” --------------- Progressive scan is disabled
Response
Unacceptable
“Error Code”[CR]
9.4.14 CR_IMAGE Command
Command
“CR_IMAGE”[CR]
Details
Get image setting status
Required data “CUSTOM1” to “CUSTOM4” is the same as “Image1” to “Image4”
displayed when selecting IMAGE on OSD menu
Acceptable
“000_%a”[CR]
%a
“DYNAMIC” --------------------------------------- Dynamic
“STAND” ------------------------------------------- Standard
“REAL” --------------------------------------------- Real
“CINEMA” ----------------------------------------- Cinema
“BLACKBOARD” -------------------------------- Blackboard
“COLORBOARD” -------------------------------- Colorboard
“CUSTOM1”~”CUSTOM4” -------------------- Image1~4
Response
Unacceptable
“Error Code”[CR] ---- When the command is invalid due to
condition such as Input source