Sanyo PLC-XK2600 RS232 Expand - Page 66

CR_P-MANETIME Command, 11.11 CR_ON-STA Command, 11.12 CR_STANDBYMODE Command, 11.13

Page 66 highlights

PLC-XK2200 /2600 /XK3010 Expand Serial Command Functional Specifications Details Response Get Power management setting status Acceptable "000_%a"[CR] "OFF Power Management is OFF %a "READY Power Management is Ready "SHUTDOWN" ---- Power Management is set to Shut Down mode Unacceptable "Error Code" [CR] 9.11.10 CR_P-MANETIME Command Command "CR_P-MANETIME"[CR] Details Get time to start Power Management Response Acceptable %a "000_%a"[CR] "001"~"030 1 minute to 30 minutes Unacceptable "Error Code" [CR] 9.11.11 CR_ON-STA Command Command "CR_ON-STA"[CR] Details Get Direct On setting status Acceptable "000_%a"[CR] Response %a "ON Direct On Start is ON "OFF Direct On Start is OFF Unacceptable "Error Code" [CR] 9.11.12 CR_STANDBYMODE Command Command "CR_STANDBYMODE" [CR] Details Get Standby Mode setting status Acceptable "000_%a"[CR] Response %a "ECO Eco Mode "NORMAL" -------- Normal Mode Unacceptable "Error Code" [CR] 9.11.13 CR_PTIMEMODE Command Command "CR_PTIMEMODE"[CR] Details Get operation mode of P-timer. Acceptable "000_%a"[CR] Response %a "COUNTUP Count up is selected "COUNTDN Count down is selected. Unacceptable "Error code"[CR] 66 / 73

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

PLC-XK2200 /2600 /XK3010
Expand Serial Command Functional Specifications
66 /
73
Details
Get Power management setting status
Acceptable
“000_%a”[CR]
%a
“OFF” -------------------------- Power Management is OFF
“READY” ---------------------- Power Management is Ready
“SHUTDOWN” ---- Power Management is set to Shut Down mode
Response
Unacceptable
“Error Code” [CR]
9.11.10 CR_P-MANETIME Command
Command
“CR_P-MANETIME”[CR]
Details
Get time to start Power Management
Acceptable
“000_%a”[CR]
%a
“001”~”030” -----------------------1 minute to 30 minutes
Response
Unacceptable
“Error Code” [CR]
9.11.11 CR_ON-STA Command
Command
“CR_ON-STA”[CR]
Details
Get Direct On setting status
Acceptable
“000_%a”[CR]
%a
“ON” -------------------------- Direct On Start is ON
“OFF” ------------------------- Direct On Start is OFF
Response
Unacceptable
“Error Code” [CR]
9.11.12 CR_STANDBYMODE Command
Command
“CR_STANDBYMODE” [CR]
Details
Get Standby Mode setting status
Acceptable
“000_%a”[CR]
%a
“ECO” -------------- Eco Mode
“NORMAL” -------- Normal Mode
Response
Unacceptable
“Error Code” [CR]
9.11.13 CR_PTIMEMODE Command
Command
“CR_PTIMEMODE”[CR]
Details
Get operation mode of P-timer.
Acceptable
“000_%a”[CR]
%a
“COUNTUP” ---------------- Count up is selected
“COUNTDN” ---------------- Count down is selected.
Response
Unacceptable
“Error code”[CR]