Sanyo PLC-XK2600 RS232 Expand - Page 69
CR_FANCONTROL Command, 11.25 CR_DELAYCTRL Command, 11.26 CR_FILH Command, 11.27 CR_FILREPL
UPC - 086483079504
View all Sanyo PLC-XK2600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
PLC-XK2200 /2600 /XK3010 Expand Serial Command Functional Specifications 9.11.24 CR_FANCONTROL Command Command "CR_FANCONTROL"[CR] Details Get selected Fan control setting status Acceptable "000_%a"[CR] "OFF Fan control is OFF Response %a "ON1 Fan control is ON1 "ON2 Fan control is ON2 Unacceptable "Error Code" [CR] 9.11.25CR_DELAYCTRL Command Command "CR_DELAYCTRL"[CR] Details Get setting status of Video delay control Acceptable "000_%1"[CR] Response %1 "ON Video delay control is active "OFF Video delay control is inactive Unacceptable "Error Code"[CR] 9.11.26 CR_FILH Command Command "CR_FILH"[CR] Details Get Filter used time Acceptable "000_%1"[CR] Response %1 "00000"~"99999 0 hour to 99999 hours Unacceptable "Error Code"[CR] 9.11.27 CR_FILREPL Command Command "CR_FILREPL"[CR] Details Get the information of Filter replacement time Acceptable "000_%1"[CR] Response %1 "1Y Over filter replacement time "1N Within filter replacement time Unacceptable "Error Code"[CR] 9.11.28 CR_FILTIMER Command Command "CR_FILTIMER" [CR] Details Get setting time which filter warning OSD is displayed Acceptable "000_%1"[CR] "2000 2000 hours Response %1 "3000 3000 hours "4000 4000 hours "OFF No OSD display Unacceptable "Error Code"[CR] 69 / 73