Sharp FP-R65CX Operation Manual - Page 17

Active Carbon Filter Indicator Light, Mist Filter Indicator Light, Mist Operation Indicator Light, - air purifier manual

Page 17 highlights

ENGLISH 3 MIST Operation Indicator Light Operating this product with water in its MIST Tray will prompt the MIST Operation Indicator Light (green) to turn on, and vaporized mist will come out automatically. To stop the The light changes accrding to the Tank condition. vaporized mist from being released, discard water from the tank and MIST Tray. Water is in • The MIST Operation Indicator Light will blink for 5 minutes when the Tank. the tank water is gone, and eventually it will turn off. • The MIST Operation Indicator Light may not correctly display if (Green) the main unit is not sitting up straight. When the sensors detect polluted air, air flow is increased to release more vaporized mist and raise its air-purifying function; a healthy environment with the appropriate humidity will be achieved. • The amount of released vaporized mist also changes, depending on humidity and temperature-related conditions. No water is in the Tank. (blinking 5min.) (OFF) 4 SENTINEL Operation Indicator Light The SENTINEL Operation Indicator Light(green) turns on when Plasmacluster Ion mode is ION AUTO or CLEAN Mode. The plasmacluster Indicator Light(mixture of blue and green) repeats its colour cycles between dark and light shades during SENTINEL Operation. The SENTINEL function detects any air environment that is favourable, for activation of mold, virus and allergen using its 4 sensors for dust, odour, temperature, and humidity. It releases "Plasmacluster ions + vaporized mist" to create an environment that controls the activity of airborne microbes. (The fan speed and amount of Plasmacluster ions are automatically increased during AUTO operation while only amount of Plasmacluster ions is automatically increased during manual fan control mode and Pollen mode.) • SENTINEL Operation will be activated automatically depends on the room temperature and humidity. Applicable range of temperature and humidity is shown in the graphs as below. • SENTINEL Operation may not be activated under the conditions of temperature and humidity when using. FRANÇAIS Molds and mildews: refer to "Kenko Jutaku no Chishiki (Knowledge of Healthy Homes)" by NPO Kenko Jutaku Suishin Kyogikai. Viruses: refer to "The Influence of Environment on the Survival of Air borne Virus Particles in Labotratory" by G. J. Harper. Allergens (House Dust): refer to Koichi Ikeda's "Shitsunai Osen no Gen'in to Taisaku (Indoor Pollution: Causes and Measures)" Plasmacluster Indicator Light 5 ACTIVE CARBON FILTER INDICATOR LIGHT Clean the Active Carbon Filter when the Active Carbon Filter Indicator Light activates. (The indicator light will activate in about 2 months, when using the unit 24 hours a day, every day.) (See Page E-19) 6 MIST FILTER INDICATOR LIGHT Clean the MIST Filter when the MIST Filter Indicator Light activates. (The indicator light will be activated in about 1 month, when using the unit with mist operation 24 hours day, every day.) (See Page E-18) E-15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

ENGLISH
FRANÇAIS
E-15
ACTIVE CARBON FILTER INDICATOR LIGHT
MIST FILTER INDICATOR LIGHT
MIST Operation Indicator Light
Operating this product with water in its MIST Tray will prompt
the MIST Operation Indicator Light (green) to turn on, and
vaporized mist will come out automatically. To stop the
vaporized mist from being released, discard water from the
tank and MIST Tray.
• The MIST Operation Indicator Light will blink for 5 minutes when
the tank water is gone, and eventually it will turn off.
• The MIST Operation Indicator Light may not correctly display if
the main unit is not sitting up straight.
When the sensors detect polluted air, air flow is increased to
release more vaporized mist and raise its air-purifying
function; a healthy environment with the appropriate humidity
will be achieved.
• The amount of released vaporized mist also changes, depending
on humidity and temperature-related conditions.
SENTINEL Operation Indicator Light
The SENTINEL Operation Indicator Light(green) turns on when Plasmacluster Ion mode is
ION AUTO or CLEAN Mode.
The plasmacluster Indicator Light(mixture of blue and green) repeats its colour cycles between
dark and light shades during SENTINEL Operation.
The SENTINEL function detects any air environment that is favourable, for activation of mold,
virus and allergen using its 4 sensors for dust, odour, temperature, and humidity. It releases
"Plasmacluster ions + vaporized mist" to create an environment that controls the activity of
airborne microbes.
(The fan speed and amount of Plasmacluster ions are automatically increased during AUTO operation while
only amount of Plasmacluster ions is automatically increased during manual fan control mode and Pollen
mode.)
Molds and mildews: refer to "Kenko Jutaku no Chishiki
(Knowledge of Healthy Homes)" by NPO Kenko Jutaku Suishin
Kyogikai.
Viruses: refer to "The Influence of Environment on the Survival
of Air borne Virus Particles in Labotratory” by G. J. Harper.
Allergens (House Dust): refer to Koichi Ikeda's "Shitsunai Osen
no Gen'in to Taisaku (Indoor Pollution: Causes and Measures)"
Clean the Active Carbon Filter when the Active Carbon Filter Indicator Light activates.
(The indicator light will activate in about 2 months, when using the unit 24 hours a day, every
day.) (See Page E-19)
Clean the MIST Filter when the MIST
Filter Indicator Light activates.
(The indicator light will be
activated
in about 1 month, when using the unit with mist
operation 24 hours day, every day.)
(See Page E-18)
3
4
5
6
(Green)
(blinking 5min.) (OFF)
The light changes accrding
to the Tank condition.
Water is in
the Tank.
No water is
in the Tank.
•SENTINEL Operation will be activated automatically depends on the room
temperature and humidity.
Applicable range of temperature and humidity is shown in the graphs as below.
• SENTINEL Operation may not be activated under the conditions of temperature and humidity when using.
Plasmacluster Indicator Light