Sharp FP-R65CX Operation Manual - Page 3

English - hepa filter

Page 3 highlights

ENGLISH ENGLISH FRANÇAIS FEATURES Plasmacluster Ion Control Your new air purifier will control the ratio of negative ions and positive ions depending on the condition of the room. • Clean Mode Approximately the same numbers of positive and negative ions are discharged. • Ion Control Mode Plenty of negative ions exist in natural surroundings such as waterfalls or forests. In this mode, negative ions will be released in an increased rate. • AUTO Plasmacluster Ion Mode The unit will switch between Clean Mode and Ion Control Mode automatically depending on the amount of impurities in the air detected by the odour and dust sensors. Washable to maintain optimum deodorization performance. • Filters 1) Washable Active Carbon Filter Absorbs odour elements. Washable to maintain optimum deodorization performance. 2) True HEPA (High Efficiency Particulate Air) Filter. High-efficiency particle collection including pollen and dust. • Mist Operation Mode New Ion Mist coats each ion with a water mist that helps to further reduce odours both in the air and tactile surfaces. • SENTINEL Operation Mode The "SENTINEL" function detects air environment that is favourable for activation of mold virus and allergen using its 4 sensors for dust, odour, temperature and humidity. CONTENTS • FOR CUSTOMER ASSISTANCE(CANADA) ... E-2 • LIMITED WARRANTY(CANADA) ........ E-3 IMPORTANT SAFETY INSTRUCTIONS .... E-4 • WARNING E-4 • CAUTIONS CONCERNING OPERATION ... E-5 • REMOTE CONTROL LIMITATIONS E-5 • INSTALLATION GUIDELINES E-5 • FILTER GUIDELINES E-5 PART NAMES E-6 • MAIN UNIT DISPLAY E-6 • INCLUDED E-6 • BACK E-7 PREPARATION E-8 • FILTER INSTALLATION E-8 • POUR WATER IN TO THE TANK E-10 • INSERTING BATTERIES IN THE REMOTE CONTROL E-11 • REMOTE CONTROL USE E-11 OPERATION E-12 • MAIN UNIT OPERATION E-12 • REMOTE CONTROL OPERATION .......... E-13 • MAIN UNIT INDICATOR E-14 CARE AND MAINTENANCE E-16 • HOW TO REMOVE THE UNIT E-16 • MIST UNIT E-18 • WASHABLE ACTIVE CARBON FILTER CARE .... E-19 • MAIN UNIT E-20 • PRE-FILTER E-20 • SENSORS E-20 • FILTER REPLACEMENT GUIDELINES E-21 TROUBLE SHOOTING E-22 SPECIFICATIONS E-23 Declaration of Conformity SHARP AIR PURIFIER FP-R65CX This ISM device complies with Canadian ICES-001 Responsible Party: SHARP ELECTRONICS OF CANADA LTD. 335 Britannia Road East Mississauga, Ontario L4Z 1W9 Canada TEL: (905) 568-7140 Thank you for purchasing the SHARP Air Purifier. Please read this manual carefully for the correct usage information. Before using this product, be sure to read the section: "Important Safety Instructions." After reading this manual, retain it in a convenient location for future reference. E-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

ENGLISH
FRANÇAIS
FEATURES
Plasmacluster Ion Control
Your new air purifier will control the ratio of
negative ions and positive ions depending
on the condition of the room.
• Clean Mode
Approximately the same numbers of posi-
tive and negative ions are discharged.
• Ion Control Mode
Plenty of negative ions exist in natural
surroundings such as waterfalls or forests.
In this mode, negative ions will be released
in an increased rate.
• AUTO Plasmacluster Ion Mode
The unit will switch between Clean Mode
and Ion Control
Mode automatically de-
pending on the amount of impurities in the
air detected by the odour and dust sensors.
Washable to maintain optimum
deodorization performance.
• Filters
1)
Washable Active Carbon Filter
Absorbs odour elements.
Washable to maintain optimum
deodorization performance.
2)
True HEPA (High Efficiency
Particulate Air) Filter.
High-efficiency particle collection includ-
ing pollen and dust.
• Mist Operation Mode
New Ion Mist coats each ion with a water
mist that helps to further reduce odours both
in the air and tactile surfaces.
• SENTINEL Operation Mode
The “SENTINEL” function detects air
environment that is favourable for activation
of mold virus and allergen using its 4
sensors for dust, odour, temperature and
humidity.
E-1
ENGLISH
Thank you for purchasing the SHARP Air Puri-
fier. Please read this manual carefully for the cor-
rect usage information. Before using this prod-
uct, be sure to read the section: “Important Safety
Instructions.”
After reading this manual, retain it in a conven-
ient location for future reference.
Declaration of Conformity
SHARP AIR PURIFIER FP-R65CX
This ISM device complies with Canadian
ICES-001
Responsible Party:
SHARP ELECTRONICS OF CANADA LTD.
335 Britannia Road East Mississauga,
Ontario L4Z 1W9 Canada
TEL: (905) 568-7140
FOR CUSTOMER ASSISTANCE(CANADA)...
E-2
LIMITED WARRANTY(CANADA)
........
E-3
IMPORTANT SAFETY INSTRUCTIONS
....
E-4
• WARNING
....................................................
E-4
CAUTIONS CONCERNING OPERATION ...
E-5
REMOTE CONTROL LIMITATIONS
............
E-5
INSTALLATION GUIDELINES
.....................
E-5
FILTER GUIDELINES
..................................
E-5
PART NAMES
..........................................
E-6
MAIN UNIT DISPLAY
...................................
E-6
• INCLUDED
...................................................
E-6
• BACK
...........................................................
E-7
PREPARATION
........................................
E-8
FILTER INSTALLATION
...............................
E-8
POUR WATER IN TO THE TANK
.............
E-10
INSERTING BATTERIES
IN THE REMOTE CONTROL
....................
E-11
REMOTE CONTROL USE
.........................
E-11
OPERATION
..........................................
E-12
MAIN UNIT OPERATION
..........................
E-12
REMOTE CONTROL OPERATION
..........
E-13
MAIN UNIT INDICATOR
...........................
E-14
CARE AND MAINTENANCE
.................
E-16
HOW TO REMOVE THE UNIT
.................
E-16
MIST UNIT
................................................
E-18
WASHABLE ACTIVE CARBON FILTER CARE
....
E-19
MAIN UNIT
................................................
E-20
• PRE-FILTER
.............................................
E-20
• SENSORS
................................................
E-20
• FILTER
REPLACEMENT
GUIDELINES
............................................
E-21
TROUBLE SHOOTING
..........................
E-22
SPECIFICATIONS
.................................
E-23
CONTENTS