Sony STR-DA5300ES Operating Instructions (Large File - 21.32 MB) - Page 120
To operate on the receiver, To confirm/save auto calibration, when GUI function is turned off
View all Sony STR-DA5300ES manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 120 highlights
Performing auto calibration For details on the auto calibration, see "9: Calibrating the appropriate speaker settings automatically (Auto Calibration)" (page 46). Refer to "Before you perform the auto calibration" (page 46) before performing the auto calibration. To operate on the receiver 1 Press SHIFT, then press MENU to set the GUI display mode to off. The menu appears on the TV screen when "GUI MODE" appears on the display. 2 Press AMP. Receiver operation is enabled. 3 Press MENU. "Auto Calibration" is displayed. 4 Press . 5 Press V/v repeatedly to select "AUTO CAL START?," then press to start the measurement. Measurement starts in five seconds. A count down is displayed. Note While the time is counting down, stand away from the measurement area to avoid measurement error. 6 Measurement starts. The measurement process will take approximately 30 seconds. Wait until the measurement process completes. To cancel auto calibration, change the volume, activate the MUTING function, switch functions, change the setting of the SPEAKERS switch of the receiver, or connect headphones. Note You cannot measure the speaker height of the surround speakers and the surround back speakers. Set this value from "SP POSI." settings in the Speaker settings menu. Tips • Operations other than turning the receiver on or off are deactivated during auto calibration. • In the following situations, the measurements may not be performed correctly or auto calibration cannot be performed. - when special speakers, such as dipole speakers are used. - when the multi zone function is used in zone 2. To confirm/save auto calibration when GUI function is turned off 1 Confirm the measurement result. When the measurement ends, a beep sounds and the measurement result appears on the display. Measurement Display Explanation result When the measurement process completes properly COMPLETE Proceed to step 2. When the measurement process fails ERROR CODE 3x See "Message list after auto calibration measurement" (page 51). 2 Press V/v repeatedly to select the item, then press . The measurement results are saved. Item Explanation RETRY Re-performs the auto calibration. SAVE EXIT Saves the measurement results and exits the setting process. WRN CHECK Displays a warning concerning the measurement results. See "When you select "WRN CHECK"" (page 51). PHASE INFO Displays the phase of each speaker (in phase/out of phase). See "When you select "PHASE INFO"". DIST.INFO Displays the measurement result for speaker distance. 120GB