TEAC TN-4D Owners Manual - Page 17
Dust cover
View all TEAC TN-4D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
ENGLISH Attaching the dust cover Dust cover Main unit Dust cover Opening and closing the dust cover Hinge Open 1 Insert the hinges completely into the hinge holders at the left and right ends of the back of the main unit. 2 Align the tops of the hinges with the dust cover hinge holders and insert them. oo Close the dust cover during playback. Since doing this prevents skipping caused by unintended contact and blocks external sound pressure, it makes noise less likely to occur. oo Do not open or close it when a record is playing. Doing so could, for example, cause the stylus to skip. oo Keep it closed whenever possible to keep dust out. Opening Hold the front edge of the dust cover and gently lift it open completely until it stops. The dust cover will stay open in this position. Closing Gently lower the dust cover until it is closed. VV Be careful not to pinch your fingers, for example, when opening and closing the dust cover. Removing the dust cover Hold both edges of the dust cover and lift it slowly to remove it along with the hinges from the unit. Then, remove the hinges from the dust cover. Changing the cartridge To change the cartridge, first remove the headshell from the tone arm. oo A Sumiko Oyster MM type cartridge is installed in the unit. oo When using an Oyster, always remove the cartridge stylus before detaching the cartridge itself from the head shell and before attaching the cartridge to the head shell. Pull the stylus knob down at a slight angle from the front of the cartridge to remove the cartridge stylus. Be careful not to touch the cantilever or stylus itself. Headshell Screws 4 Connect the shell lead terminals to the cartridge. oo The signals and colors of the shell leads are shown below. Signal Left channel + Left channel − Right channel + Right channel − Color White Blue Red Green Nuts Shell leads Cartridge Stylus, Stylus knob cantilever 5 Balance the tone arm and adjust the tracking force. Follow the procedures in "Balancing the tone arm and adjusting the tracking force" on page 15. 1 Disconnect the shell lead terminals from the cartridge. 2 Loosen the screws and remove the cartridge. 3 Attach the new cartridge and tighten the screws. See the illustration below for the position of the screws when attached. Precautions when changing the cartridge The weight of cartridges that can be used with this unit is limited. See "Tone arm" on page 20. Also check the acceptable cartridge weight (with the included head shell) shown on the same page when changing the head shell. Using MC cartridges The equalizer amplifier built into this unit is for MM cartridges. It does not support MC cartridges. To use an MC cartridge, connect this unit to a phono equalizer amplifier that supports MC cartridges or an amplifier with an MC phono input connector, for example. Then, set this unit's PHONO EQ (audio output) setting switch to THRU. 52.8 ±0.5 mm 17