To search for tones, leave the tones for A and B at 0.
View all Uniden BCD325P2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 111 highlights
Notes: For two-tone pages, enter the tones (in Hz) for tone A and tone B. For one-tone pages using short tones between 1.25 and 3.75 seconds, enter tone for tone A and 0 for B. For long-tone pages, such as group pages of more than 3.75 seconds, enter 0 for A and the tone for B. To search for tones, leave the tones for A and B at 0. 1. Scroll to 'Edit Tone A' and press E/yes. 2. Enter the tone and press E/yes to save and exit. 3. Scroll to 'Edit Tone B' and press E/yes. 4. Enter the tone and press E/yes to save and exit. 5. Press Menu to return. 6. Scroll to 'Set Delay Time' and press E/yes. 7. Scroll to one of 3 settings and press E/yes to save and exit. Off - the scanner resumes standby as soon as the carrier drops after a page. 1-30 - (seconds): the scanner resumes standby mode after the carrier drops and the selected time expires. Infinite - you must press Hold after a page to resume standby mode. 8. Scroll to 'Set Alert' and press E/yes. 9. Scroll to 'Set Alert Tone' and press E/yes. 10. At 'Set Tone' scroll to the alert (Alert 1-9 or Off) and press E/yes. 11. At 'Set Level' scroll to 'Level 1-15 or Auto' (the scanner sets the alert beep to the master volume level) and press E/yes. 12. Scroll to 'Set Alert Light' and press E/yes. 13. Scroll to On, Off, Slow Blink, or Fast Blink and press E/yes. 14. Press Menu to return. 15. Scroll to 'Set Record' and press E/yes. 16. Scroll to On or Off and press E/yes to save and exit. 17. Press Menu to return then scroll to 'Tone-Out 2' and repeat to program more tones. 111