3ware Escalade ATA RAID Controller Installation Guide 3ware Disk Array Configuration Available Drives: Disk Arrays: *Array Unit 0 - 4 drive 64K RAID 0 Port 0 - QUANTUM FIREBALLP LM30 Port 1 - QUANTUM FIREBALLP LM30 Port 2 - QUANTUM FIREBALLP LM30 Port 3 - QUANTUM FIREBALLP LM30 120.0GB 30.0GB 30.0GB 30.0GB 30.0GB Create Array Delete Array Maintain Array Rebuild Array Alt-F1 Help Previous/Next $ Toggle Hot Spare EnterSelect/Deselect F6 Restore Initial Values Esc Cancel F8 Done Figure 11. Delete Disk Array Display Navigate to the Delete Array button and hit Enter to bring up the Delete Disk Array display. Check that the correct drives are listed. Select the OK key to confirm deleting the array or Cancel to reject it. Recall that the array is not actually deleted and no data will be overwritten until you have finished making all your changes and selected the F8 key. How to maintain or verify a disk array The Maintain Disk Array (see Figure 12) shows the current disk array configuration that you have selected. The array's Write Cache State can be changed. Refer to Select write cache properties paragraph in the Creating a disk array section. Verify Array can be specified as no or yes. The default is no. Yes launches a foreground process that checks the data integrity of a fault tolerant 36 www.3ware.com 3ware Disk Array Configuration Utility array. If the verify array process determines that the mirrored drives are not identical or the parity is not correct, the array is degraded and the rebuild process is launched. Maintain Disk Array The array listed below can have its write cache state changed. Verify checks the data integrity of a fault tolerant array. Array Unit 2 - 2 drive Mirror Port 2 - QUANTUM FIREBALLP LM30 Port 3 - QUANTUM FIREBALLP LM30 30.0GB 30.0GB 30.0GB Array's Write Cache State: enabled Verify Array: no OK Cancel Alt-F1 Help Previous/Next Enter Change Value Esc Cancel Figure 12. Maintain Disk Array Display Note: Fault tolerant arrays can not be verified until after they are initialized. For RAID 1 and 10 arrays the initial verify must first be done in 3DM, otherwise the initialization will not be done. Rebuilding a mirrored disk array Escalade ATA RAID Controllers allow you to create fault tolerant disk arrays by selecting a mirrored RAID 1 or RAID 10 array. These disk arrays store identical data on two or more drives to protect against drive failure. If one or more of the drives of a mirrored www.3ware.com 37