A.2 Specifications Input Characteristics Input Voltage Range Range 1 Range 2 Input Frequency Range Maximum Input ac Current Inrush Current Efficiency Min Nom Max 90V 115V 140V 180V 230V 264V 47 Hz to 63 Hz 5.5A max at 115Vac 2.75A max. at 230Vac, maximum load 18A cold start 18A warm start 65% min. at nominal input, maximum load Output Characteristics Output Voltage +5V +12V -12V +5VSB +3V3 Load Range Min Max 0.5A 9.5A 2.0A 15.0A 0A 0.2A 0A 1.5A 1.0A 14.0A Regulation Min Max -5% +5% -5% +5% -10% +10% -5% +5% -5% +5% Ripple Max 50mVp-p 120mVp-p 200mVp-p 100mVp-p 50mVp-p Over-Voltage Protection (OVP) Output Voltage +5V +12V +3.3V +5VSB -12V Maximum Voltage 7V 15.6V 5V 7V -15.6V NOTE The power supply will shut down and latch off for shorting +5V, +12V, -12V, or +3.3V. By shorting +5VSB, the power supply can latch down or automatically recover when the fault condition is removed. ASUS AP160R-S 1U Rackmount Server 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

ASUS AP160R-S 1U Rackmount Server
41
Input Characteristics
A.2
Specifications
Output Characteristics
Over-Voltage Protection (OVP)
Input Voltage Range
Min
Nom
Max
Range 1
90V
115V
140V
Range 2
180V
230V
264V
Input Frequency Range
47 Hz to 63 Hz
Maximum Input ac Current
5.5A max at 115Vac
2.75A max. at 230Vac, maximum load
Inrush Current
18A cold start
18A warm start
Efficiency
65% min. at nominal input,
maximum load
Output
Load Range
Regulation
Ripple
Voltage
Min
Max
Min
Max
Max
+5V
0.5A
9.5A
-5%
+5%
50mV
p-p
+12V
2.0A
15.0A
-5%
+5%
120mV
p-p
-12V
0A
0.2A
-10%
+10%
200mV
p-p
+5VSB
0A
1.5A
-5%
+5%
100mV
p-p
+3V3
1.0A
14.0A
-5%
+5%
50mV
p-p
Output Voltage
Maximum Voltage
+5V
7V
+12V
15.6V
+3.3V
5V
+5VSB
7V
-12V
-15.6V
NOTE
The power supply will shut down and latch off for shorting +5V,
+12V, -12V, or +3.3V. By shorting +5VSB, the power supply can
latch down or automatically recover when the fault condition is
removed.