Asus AP2300 AP2300 Server in English

Asus AP2300 Manual

Asus AP2300 manual content summary:

  • Asus AP2300 | AP2300 Server in English - Page 1
    AP2300 Dual Pentium® III Server Platform Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 2
    AS A COMMITMENT BY ASUS. ASUS ASSUMES NO RESPONSIBILITY OR LIABILITY FOR ANY ERRORS OR INACCURACIES THAT MAY APPEAR IN THIS MANUAL, INCLUDING THE PRODUCTS AND SOFTWARE DESCRIBED IN IT. Copyright © 2000 ASUSTeK COMPUTER INC. All Rights Reserved. Product Name: AP2300 Manual Revision: 1.00 E540
  • Asus AP2300 | AP2300 Server in English - Page 3
    -3449 [email protected] Technical Support MB/Others (Tel): +886-2-2890-7121 (English) Notebook (Tel): +886-2-2890-7122 (English) Desktop/Server (Tel):+886-2-2890-7123 (English) Fax: +886-2-2895-9254 Email: [email protected] WWW: www.asus.com.tw FTP: ftp.asus.com.tw/pub/ASUS ASUS COMPUTER
  • Asus AP2300 | AP2300 Server in English - Page 4
    this Manual is Organized 7 Symbols 7 1-2 Component Checklist 8 Standard components 8 Optional components 8 1-3 Features 9 Motherboard: ASUS CUR-DLS Fan Control Board Settings 19 4-3 Motherboard Placement 20 Motherboard Spacers 20 Motherboard Screws 20 Chassis Intrusion Connector 20
  • Asus AP2300 | AP2300 Server in English - Page 5
    Power Supply Information 38 4-18 Power Supply Requirement 40 Power Supply Requirement Calculation Table 40 5. Appendix 41 5-1 SCSI Cable Limits 41 5-2 Glossary 42 Index 43 AP2300 Hardware Reference Guide 5
  • Asus AP2300 | AP2300 Server in English - Page 6
    radio frequency energy and, if not installed and used in accordance with manufacturer's instructions, may cause harmful interference to radio communications. However, there is no guarantee Radio Interference Regulations of the Canadian Department of Communications. 6 AP2300 Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 7
    guide is intended for experienced users and integrators with hardware knowledge of personal computers. You should also read all documentation and manuals PHILIP (CROSS) SCREW DRIVER: Tools required to install or remove the components in this server. STANDARD (FLAT) SCREW DRIVER: Tools required to
  • Asus AP2300 | AP2300 Server in English - Page 8
    a guideline as to the necessary components for a server. Standard components Motherboard: CUR-DLS Chassis: AS-30 Power Supply: ATX Processor (CPU): terminator for 68-pin SCSI cables User's Manuals: CD-ROM, motherboard, hardware guide Optional components RAID Controller: PCI-DA2200 or
  • Asus AP2300 | AP2300 Server in English - Page 9
    The AP2300 is configured on the ASUS CUR-DLS smart motherboard which uses the ServerSetTM chipset from ServerWorks®, supporting dual For additional features and details, read the motherboard User's Manual included with this server package. Motherboard: ASUS CUR-DLS • Processor: Dual Intel® Pentium
  • Asus AP2300 | AP2300 Server in English - Page 10
    instructions any time you are connecting or disconnecting any devices. Operation Safety IMPORTANT • Any operation on this server must be conducted by cer- tified or experienced engineers. • Before operating your server, carefully read all the manuals this server. 10 AP2300 Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 11
    cable in conjunction with a properly grounded electrical outlet to avoid electrical shock. IMPORTANT Motherboards, adapters, and disk drives are sensitive to static electricity discharge. These devices the devices carefully in order to prevent permanent damage. AP2300 Hardware Reference Guide 11
  • Asus AP2300 | AP2300 Server in English - Page 12
    1. Introduction (This page was intentionally left blank) 1. Introduction 12 AP2300 Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 13
    7. Drive Expansion Bay 8. Side Panel Handle 9. Side Panel Screws 10. Metal Door Lock 11. Hot-Swap Trays 12. Hard Drive Fan Module 13. Chassis Stabilizers AP2300 Hardware Reference Guide 12 13 13
  • Asus AP2300 | AP2300 Server in English - Page 14
    2, RJ45 Port (LAN) 7. Serial Port COM1 8. Parallel Port 9. Serial Port COM2 10. VGA Connector 11. Rear Fan Module 12. Chassis Stabilizer Server Back Side 14 AP2300 Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 15
    II. Components BBaacckk SSiiddee 2. Overview Left Side 2. System Overview • 2-3 Server Left Side 1 5 2 3 4 1. Power Supply 2. Motherboard 3. Chassis Intrusion Micro Switch 4. Chassis Stabilizer 5. Rear Fans Server Left Side AP2300 Hardware Reference Guide 15
  • Asus AP2300 | AP2300 Server in English - Page 16
    Setup This server does not come with any pre-installed software. When booting your server for the first time, make BIOS settings by following the motherboard User's Manual. 16 AP2300 Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 17
    two screws on the back of the server. To open the top panel, remove the screws with a screw driver. NOTE: You do not have to open the top panel before removing the left panel. The side panels spring to remove the front door. 4. Hardware Setup Opening the Chassis AP2300 Hardware Reference Guide 17
  • Asus AP2300 | AP2300 Server in English - Page 18
    the fan, remove the screws. IMPORTANT: Usually, the rotation of the fan sends air toward the manufacturer's label on the center of the fan. 18 AP2300 Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 19
    OFF ON OFF ON OFF OFF OFF OFF SET4 ON OFF ON OFF ON OFF ON OFF Number of Fans 1 2 (Default) 3 4 5 6 7 8 4. Hardware Setup Rear Fans AP2300 Hardware Reference Guide 19
  • Asus AP2300 | AP2300 Server in English - Page 20
    screws are necessary to provide the needed stabilization to support all the motherboard expansion cards used in this chassis. Motherboard Spacers Place four spacers in the areas circled on the chassis. Extended Expansion Card Guide Spacer Motherboard Screws Place nine screws in the areas circled on
  • Asus AP2300 | AP2300 Server in English - Page 21
    location. Plastic keepers protect the cables from contacting with the fans and other devices. Make sure that all cables are properly secured. 4. Hardware Setup Motherboard Placement Floppy Drive Cable IDE Cable 68-pin SCSI Cable 68-pin SCSI Cable Cable Connections The cables connect to the
  • Asus AP2300 | AP2300 Server in English - Page 22
    with the optional S370 terminator to improve signaling. For memory installation, refer to the motherboard User's Manual. 4. Hardware Setup CPU Installing S370 CPU Locate the ZIF socket and open it by close the socket's lever while holding down the CPU. 22 AP2300 Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 23
    fan heatsink over the mounted CPU. Attach the heatsink clip over the clip attach point as shown above. Connect the fan power plug to the motherboard. To remove the fan heatsink, reverse the installation procedure. 4. Hardware Setup Fan Heatsink AP2300 Hardware Reference Guide 23
  • Asus AP2300 | AP2300 Server in English - Page 24
    . The connection diagram is given here. 4. Hardware Setup Chassis Intrusion Switch Cable Chassis Intrusion Switches (one on each side) from the two Chassis Intrusion Switches Motherboard's Chassis Intrusion Lead (No Connection) GND Chasis Signal 24 AP2300 Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 25
    installed. 4. Hardware Setup Expansion Cards Contact CAUTION Make sure that the total amperage of your installed expansion cards does not exceed the system power specification. AP2300 Hardware Reference Guide 25
  • Asus AP2300 | AP2300 Server in English - Page 26
    disk drive. Four screws are provided (as boxed) for mounting a 6 inch device such as a CD-ROM or tape drive. 4. Hardware Setup Fixed Storage Devices 26 AP2300 Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 27
    After releasing the device bay cover clips, pry the cover away from the chassis using a screw driver from the front. Storage Device Spacers A floppy drive spacer is used to cover the floppy drive for each storage device. Floppy Drive Spacer Fixed Device Spacer AP2300 Hardware Reference Guide 27
  • Asus AP2300 | AP2300 Server in English - Page 28
    replaced or "swapped." The main hard drives are mounted in internal hot-swap trays for easy replacement. The AP2300 hot-swap bay has two different models: Five-tray hot-swap bay and three-tray hot-swap bay. aluminum carrier only for a single SCSI hard disk drive. 28 AP2300 Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 29
    with a small screwdriver. Remove the six retaining screws as circled above and then the entire hot-swap bay can be slid out of the chassis. AP2300 Hardware Reference Guide 29
  • Asus AP2300 | AP2300 Server in English - Page 30
    drives. These fans can be removed by using a small screw driver to push the eject mechanism in the fan module. The eject mechanism (6cm) fans secured by four screws on each fan. The ASMA (ASUS Server Management Agent) software will report an error message when any of AP2300 Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 31
    is rebuilding (*) On Slow Flash Hot-spare hard disk drive ready (*) Fast Flash On Hard disk drive failure/short circuits * Must work with ASMA software. AP2300 Hardware Reference Guide 31
  • Asus AP2300 | AP2300 Server in English - Page 32
    placed on this bottom SCSI connector. 1" Tray Connector #5 or 1 1" Tray Connector #4 or 2 Fan Control Board Connector 1" Tray Connector #3 1" Tray Connector #2 or 4 1" Tray Connector #1 or 5 32 AP2300 Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 33
    09 Tray3 05 Tray2 03 Tray1 01 Bottom Bay Resulting SCSI ID#s Top Bay ID Tray5 12 Tray4 08 Tray3 04 Tray2 02 Tray1 00 manual for any additional devices that you may install for details on how to set its ID number. 4. Hardware Setup SCSI ID Setting AP2300 Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 34
    Male Terminator for SCSI Backplane • 4-15 SMBus Connector To use SMBus devices, connect the motherboard's SMBus connector to the SMB In connector on the DA-BP5E SCSI backplane board. Another SMBCLK SMB In SMB Out CUR-DLS Motherboard DA-BP5E SCSI Backplane Board 34 AP2300 Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 35
    load but two modules combined do not provide 600W. If one power module fails, 300W load is supported using one power module. IMPORTANT Before turning on the server, make sure the power input voltage is 400W standard power supply module may be ordered on demand. AP2300 Hardware Reference Guide 35
  • Asus AP2300 | AP2300 Server in English - Page 36
    . Remove the four screws securing the power supply unit, and then slide the power supply unit toward the front of the chassis (as pointed). 36 AP2300 Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 37
    and TUV safety. EMI The power system, operating with resistive load, meets FCC class B and CISPR 22 class B conducted limits. 4. Hardware Setup Redundant Power Supply AP2300 Hardware Reference Guide 37
  • Asus AP2300 | AP2300 Server in English - Page 38
    5.25V 50mVp-p 3 11.40V 12.00V 12.60V 120mVp-p 4 -4.50V -5.00V -5.50V 120mVp-p 5 -10.92V -12.00V -13.20V 120mV p-p 6 4.75V 5.00V 5.25V 50mVp-p 38 AP2300 Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 39
    and TUV safety. EMI The power system, operating with resistive load, meets FCC class B and CISPR 22 class B conducted limits. 4. Hardware Setup Standard Power Supply AP2300 Hardware Reference Guide 39
  • Asus AP2300 | AP2300 Server in English - Page 40
    4-18 Power Supply Requirement Power Supply Requirement Calculation Table Item Volts Amp x Qty. = TotalAmp Total Watts Motherboard* 3.3V 5.0V 12.0V 54.78 147.40 4.00 Hard Drive 5.0V 12.0V x = on 12.0Volts) installed. 4. Hardware Setup Power Consumption 40 AP2300 Hardware Reference Guide
  • Asus AP2300 | AP2300 Server in English - Page 41
    that it may have. Exceeding the length may cause problems mounting or using any one of the SCSI devices. the SCSI controller. • A maximum of 15 devices may be connected to the motherboard (three connectors) at one time. NOTE • A total of 15 "Ultra2 Cable Limits AP2300 Hardware Reference Guide 41
  • Asus AP2300 | AP2300 Server in English - Page 42
    Asus Server Management Agent) ASUS Server Management Agent is an SNMP software that provides hardware monitoring information to the Network Management Station (NMS). ASMA can report the computer down the computer system. LVDS computer support hot-swapping. SCSI (Small Computer or computer when power
  • Asus AP2300 | AP2300 Server in English - Page 43
    28 L LAN 9 LED 16 Hard Drive Access 13 Power 13, 16 Left Panel 18 Lock 13 E ECC 9 EMI 37, 39 Expansion Cards 8, 25 Expansion Card Guide 15, 25 M Motherboard 8, 15 Placement 20 Spacers 20 AP2300 Hardware Reference Guide 43
  • Asus AP2300 | AP2300 Server in English - Page 44
    19 Rear Fans 15 Right Panel 17 RJ45 Port 9, 14 S Safeguards 10 SCA 29 Screws Side Panel 13 SCSI Backplane 9, 32 Cable Limits 41 44 AP2300 Hardware Reference Guide
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

AP2300
Dual Pentium
®
III Server Platform
Hardware Reference Guide