Asus AP8000 Hardware Reference - Page 20

Install Retention, Mechanisms, Mechanism, Brace Bars

Page 20 highlights

IV. Hardware Setup • 4-3. Central Processing Unit (CPU) This server supports two processors which requires one retention mechanism for each processor. Before installing the CPU, secure the motherboard on the rubber pad and metal baseboard. (See page 18.) When only one processor is used, the other Slot 2 connector must be terminated with the provided front side bus termination module. Captive Nut Long Screw (aligned with spacers) Short Screw One Dot Two Dots Install Retention Mechanisms The retention mechanism parts have a left and a right side. The left side has a single dot and the right side has two dots (when holding the motherboard with the ATX connectors to the left). Place the retention mechanisms' holes over the screws and the Slot2. Screw four captive nuts onto the inner screws (3 circled in the picture). Do not place the other captive nuts yet. Install Retention Mechanism Brace Bars Place the retention mechanism brace bar into the groove on the top of the retention mechanism as shown. Retention Mechanism Brace Bar IV. Hardware Setup CPU 20 AP8000 Hardware Reference Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

20
IV. Hardware Setup
IV. Hardware Setup
AP8000 Hardware Reference Guide
This server supports two processors which requires one retention mecha-
nism for each processor. Before installing the CPU, secure the mother-
board on the rubber pad and metal baseboard. (See page 18.)
When only one processor is used, the other Slot 2 connector must be termi-
nated with the provided front side bus termination module.
• 4-3. Central Processing Unit (CPU)
CPU
Captive Nut
Long Screw (aligned with spacers)
Short Screw
Install Retention
Mechanisms
The retention mechanism parts
have a left and a right side. The
left side has a single dot and the
right side has two dots
(when
holding the motherboard with the
ATX connectors to the left). Place
the retention mechanisms’ holes
over the screws and the Slot2.
Screw four captive nuts onto the
inner screws (3 circled in the pic-
ture). Do not place the other cap-
tive nuts yet.
Two Dots
One Dot
Install Retention
Mechanism
Brace Bars
Place the retention mechanism
brace bar into the groove on the
top of the retention mechanism
as shown.
Retention Mechanism Brace Bar