Asus AZCRB Global Array Manager Transition Tool - Page 27

ASUS Zero-Channel RAID Board, READY, ONLIN, Axx-xx, ONLIN A01-01, MegaRAID Configuration Software,

Page 27 highlights

3. Use the arrow keys to select a specific physical drive, then press the to associate the selected drive with the current array. The indicator for the selected drive changes from READY to ONLIN Axx-xx. MegaRAID BIOS Config Utility(40-Ld) Ver5.40 Apr 21, 2003 Standard:Adapter-01 New Configuration - ARRAY SELECTION MENU Management Configure ID Initialize 0 Objects Format 1 Rebuild Check Consistency 2 Channel-1 ONLIN A01-01 ONLIN A01-02 ONLIN A01-03 3 ONLIN A01-04 4 5 6 Channel-2 ID 0 1 2 3 4 5 6 >> where Axx-xx means: Ch-1 ID-0 DISK 17521MB FUJITSU MAN3184MC 0109 A[array number]-[drive number] SPACE-Array,ENTER-Configure,F2-Drive Information,F3-Logical Drives,F4-HotSpare For example, ONLIN A01-01 means disk drive 1 in array 1. If possible, use identical drives (with the same type and capacity) in one array. If you use drives of different capacities in one array, all the drives are treated as if they have the capacity of the smallest drive in the array. 4. Follow steps 4 to 12 in section "5.2 Easy Configuration." For instructions on creating multiple arrays, refer to the MegaRAID Configuration Software Guide in the support CD. ASUS Zero-Channel RAID Board 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

ASUS Zero-Channel RAID Board
27
MegaRAID BIOS Config Utility(40-Ld) Ver5.40 Apr
21, 2003 Standard:Adapter-01
SPACE-Array,ENTER-Configure,F2-Drive Information,F3-Logical Drives,F4-HotSpare
Ch-1
ID-0
DISK
17521MB
FUJITSU
MAN3184MC
0109
Management
Configure
Initialize
Objects
Format
Rebuild
Check Consistency
New Configuration - ARRAY SELECTION MENU
ID
Channel-1
ONLIN A01-01
ONLIN A01-02
ONLIN A01-03
ONLIN A01-04
0
1
6
5
4
3
2
ID
Channel-2
0
1
6
5
4
3
2
3.
Use the arrow keys to select a
specific physical drive, then press
the <Space bar> to associate the
selected drive with the current array.
The indicator for the selected drive
changes from
READY
to
ONLIN
Axx-xx
.
>> where
Axx-xx
means:
A[array number]-[drive number]
For example,
ONLIN A01-01
means
disk drive 1 in array 1.
If possible, use identical drives (with the same type and capacity) in one array.
If you use drives of different capacities in one array, all the drives are treated
as if they have the capacity of the
smallest
drive in the array.
4.
Follow steps 4 to 12 in section
5.2
Easy Configuration.
For instructions on
creating multiple arrays, refer to the
MegaRAID Configuration Software
Guide
in the support CD.