Extension Fan 1-3 Min. Duty Cycle% [60]
View all Asus SABERTOOTH Z170 MARK 1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 108 highlights
Extension Fan 1-3 Upper Temperature [70] Use the or keys to adjust the upper limit of the Extension Fan 1-3 temperature. The values range from 20 to 75. Extension Fan 1-3 Max. Duty Cycle (%) [100] Use the or keys to adjust the maximum Extension Fan 1-3 duty cycle. The values range from 20% to 100%. When the CPU temperature reaches the upper limit, the Extension Fan 1-3 will operate at the maximum duty cycle. Extension Fan 1-3 Middle Temperature [45] Use the or keys to adjust the middle limit of the Extension Fan 1-3 temperature. The values range from 20 to 75. Extension Fan 1-3 Middle. Duty Cycle (%) [60] Use the or keys to adjust the maximum Extension Fan 1-3 duty cycle. The values range from 20% to 100%. When the CPU temperature reaches the upper limit, the Extension Fan 1-3 will operate at the maximum duty cycle. Extension Fan 1-3 Lower Temperature [40] Use the or keys to adjust the lower limit of the Extension Fan 1-3 temperature. The values range from 20 to 75. The Extension Fan 1-3 will operate at the minimum duty cycle when the temperature is lower than the limit. Extension Fan 1-3 Min. Duty Cycle(%) [60] Use the or keys to adjust the minimum Extension Fan 1-3 duty cycle. The values range from 0% to 100%. When the CPU temperature is under the limit, the Extension Fan 1-3 will operate at the minimum duty cycle. Allow Fan Stop [Disabled] This item allow the fan to run at 0% duty cycle when the temperature of the source is dropped below the lower temperature. Configuration options: [Disabled] [Enabled] Water Pump Control [Disabled] [Disabled] Disable the Water Pump control feature. [DC mode] Enable the Water Pump control in DC mode for 3-pin chassis fan. [PWM mode] Enable the Water Pump control in PWM mode for 4-pin chassis fan. The following items appear only when you set the Water Pump Control to [DC mode] or [PWM mode]. Water Pump Upper Temperature [70] Use the or keys to adjust the upper limit of the Water Pump temperature. The values range from 20 to 75. Water Pump Max. Duty Cycle (%) [100] Use the or keys to adjust the maximum Water Pump duty cycle. The values range from 20% to 100%. When the CPU temperature reaches the upper limit, the Water Pump will operate at the maximum duty cycle. Water Pump Middle Temperature [45] Use the or keys to adjust the middle limit of the Water Pump temperature. The values range from 20 to 75. Chapter 3 3-44 Chapter 3: BIOS Setup