18 en | Controlling Allegiant Series Video Switchers IntuiKey Keyboard Error Name Error 53 Switcher Empty Error 55 SEQUENCE Priority Error 56 SEQUENCE Request Error 58 SEQUENCE Request Error 60 PROGRAM Request Error 62 PROGRAM Request Error 63 PROGRAM Request Error 70 Monitor No Allocated to Group Error 71 Step Monitor Required Error 78 Must Enter Alarm Number Error 80 Trunk Not Available Error 81 Satellite Trunk Seized Error 89 Internal Stack Error Error 90 Keyboard Entry Undefined Error 92 Keyboard Entry Out of Range Error 94 Keyboard Entry Invalid Error 95 Keyboard Entry Incomplete Error 96 * (STAR) Undefined Error 128 No Communications Description The user has attempted to control a sequence using the NEXT, PREV, RUN, or HOLD keys, without there being a sequence loaded. The switcher sequence being requested or cleared requires monitors that are in use by a user of equal or higher priority. Contact a user with higher priority or have the system administrator clear the monitors in question. The user has attempted to load a sequence that is being edited in the PROGRAM mode. Once editing is complete, the sequence may be loaded. The sequence being requested is a relative sequence, and the user is only permitted access to absolute sequences. The user has attempted to program a sequence that is currently running. The sequence must first be stopped before any editing can be performed. The user has attempted to program a new sequence when the sequence memory space has been depleted. Delete unused sequences, then program the new sequence. Another user is already programming a sequence on this monitor. This monitor cannot be used for alarm operations; it has not been designated as alarm-capable by the system programmer. A group of alarm monitors may not have an armed Review (display) monitor without having armed Step (sequence) monitors. A specific alarm number must be entered when arming or disarming an alarm. An attempt was made to access a remote camera connected to a satellite system, but no unused trunk lines are currently available. The camera currently viewed has changed because an operator with a higher priority has selected a different camera that seized the trunk line from the satellite. A stack overflow within the system has occurred. Report this to the manufacturer. The keyboard entry is not defined. Check the appropriate section of the instruction manual for the desired operation and try again. The data entered for a valid command was not in the permissible range. Check the appropriate section of the instruction manual for acceptable ranges for the command in question and try again. An invalid character was received from the keyboard. Usually this indicates a communications error. Verify that the keyboard-tosystem cable is not producing an intermittent connection. The control sequence sent from the keyboard was incomplete. Usually this indicates a communications error. Verify that the keyboard-to-system cable is not producing an intermittent connection. The * key has been pressed, but there is no definition for this button. The keyboard cannot communicate with the Allegiant. F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

18
en | Controlling Allegiant Series Video Switchers
IntuiKey Keyboard
F.01U.127.291 | 1.93 | 2009.03
User Manual
Bosch Security System, Inc.
Error 53
Switcher Empty
The user has attempted to control a sequence using the NEXT,
PREV, RUN, or HOLD keys, without there being a sequence loaded.
Error 55
SEQUENCE Priority
The switcher sequence being requested or cleared requires
monitors that are in use by a user of equal or higher priority.
Contact a user with higher priority or have the system administrator
clear the monitors in question.
Error 56
SEQUENCE Request
The user has attempted to load a sequence that is being edited in
the PROGRAM mode. Once editing is complete, the sequence may
be loaded.
Error 58
SEQUENCE Request
The sequence being requested is a relative sequence, and the user
is only permitted access to absolute sequences.
Error 60
PROGRAM Request
The user has attempted to program a sequence that is currently
running. The sequence must first be stopped before any editing can
be performed.
Error 62
PROGRAM Request
The user has attempted to program a new sequence when the
sequence memory space has been depleted. Delete unused
sequences, then program the new sequence.
Error 63
PROGRAM Request
Another user is already programming a sequence on this monitor.
Error 70
Monitor No Allocated to Group
This monitor cannot be used for alarm operations; it has not been
designated as alarm-capable by the system programmer.
Error 71
Step Monitor Required
A group of alarm monitors may not have an armed Review (display)
monitor without having armed Step (sequence) monitors.
Error 78
Must Enter Alarm Number
A specific alarm number must be entered when arming or disarming
an alarm.
Error 80
Trunk Not Available
An attempt was made to access a remote camera connected to a
satellite system, but no unused trunk lines are currently available.
Error 81
Satellite Trunk Seized
The camera currently viewed has changed because an operator with
a higher priority has selected a different camera that seized the
trunk line from the satellite.
Error 89
Internal Stack Error
A stack overflow within the system has occurred. Report this to the
manufacturer.
Error 90
Keyboard Entry Undefined
The keyboard entry is not defined. Check the appropriate section of
the instruction manual for the desired operation and try again.
Error 92
Keyboard Entry Out of Range
The data entered for a valid command was not in the permissible
range. Check the appropriate section of the instruction manual for
acceptable ranges for the command in question and try again.
Error 94
Keyboard Entry Invalid
An invalid character was received from the keyboard. Usually this
indicates a communications error. Verify that the keyboard-to-
system cable is not producing an intermittent connection.
Error 95
Keyboard Entry Incomplete
The control sequence sent from the keyboard was incomplete.
Usually this indicates a communications error. Verify that the
keyboard-to-system cable is not producing an intermittent
connection.
Error 96
* (STAR) Undefined
The * key has been pressed, but there is no definition for this
button.
Error 128
No Communications
The keyboard cannot communicate with the Allegiant.
Error
Name
Description