Table of extended option output, Memory SW-0b
View all Brother International BAS-311F-0 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 208 highlights
Chapter 4 Extended Option Output Table of extended option output Extended option output No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Common output (condition) *1 Part name Condition 2 stage tension Memory SW-0b ON Air wiper Memory SW-09 ON Pattern engraving drill Memory SW-10 ON Auto eject Memory SW-03 ON Upper/lower engraving Memory SW-10 ON Right work clamp turnover Memory SW-19 ON Left work clamp turnover Memory SW-19 ON Signal tower green Signal tower yellow Signal tower red NEEDLE FLIP FOOT LCLAMP RCLAMP Memory SW-15 ON Memory SW-15 ON Memory SW-15 ON DIPSWB-4 ON DIPSWA-6 ON DIPSWC-6 ON When 2 stage pressure bar is used For the air type Connector *2 Connector No. Pin No. 5 6 P4(AIR) 6 7 7 1 2 3 4 P21(EXOUT) 5 6 7 8 8 4 P4(AIR) 3 2 1 *1 Input available for optional parts. It is not used as extended option input if conditions are met. *2 Connector number and pin number on the main circuit board in the control box • The common terminal of connector P4 (AIR) is pin No. 11 at +24V. • The common terminal of connector P21 (EXOUT) is pin No. 9 or 10 at +24V. Programmer 207