Brother International BES-941BC Instruction Manual - English - Page 165
Cooling fan motor stop A Press R., main PCB CPU
View all Brother International BES-941BC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 165 highlights
Chapter 9 List of Error Messages Code Error Messages Error Measures E-D0 E-D1 E-D2 E-D3 E-E1 E-E2 E-E3 E-E4 E-E5 E-E6 Power PC board error Cooling fan motor stop Power PC board error Cooling fan motor stop B Tum the power off. Turn the power off and on once. If the same error occurs again, the power PCB is faulty. Turn off the power and check the fan harness. Turn on the power again. If the same error occurs again, the fan or the power PCB is faulty. Power voltage upper limit error Power voltage upper limit error Power voltage lower limit error Power voltage lower limit error (1) The voltage setting is improper. -> Set it again. (2) Press the or turn on the F/B switch on the head to STOP either side. If the same error occurs again, the power PCB or the power supply is faulty. X-axis pulse motor overcurrent stop Turn off the power Y-axis pulse motor overcurrent stop Turn off the power X-axis pulse motor overcurrent stop Y-axis pulse motor overcurrent stop Turn the power off and on once. If the same error occurs again, the pulse motor or the main PCB is faulty. Exhaust fan motor stop Hook motor error ERROR E5 Cooling fan motor stop A Press R. Lower shaft communication error Over-run error during interfacing to main PCB CPU Turn off the power and check the fan harness. Turn on the power again. If the same error occurs again, the fan or the power PCB is faulty. Turn the power off and on once. If the same error occurs again, the main PCB is faulty. ERROR E6 Framing error during interfacing to main PCB CPU E-E7 ERROR E7 Parity error during interfacing to main PCB CPU E-E8 ERROR E8 E-E9 ERROR E9 E-EA ERROR EA E-EB ERROR EB E-EC ERROR EC E-ED ERROR ED Receiving time up error during interfacing to main PCB CPU Send/Receive inconsistent error during interfacing to main PCB CPU ACK code receiving error during interfacing to main PCB CPU Send/Receive ID code error during interfacing to main PCB CPU Send data checksum error during interfacing to main PCB CPU Data empty error during interfacing to main PCB CPU E-EF ERROR EF Receiving error on interface E-F1 ERROR F1 E-F2 ERROR F2 Send time up error Request-to-waiting time up error This is not usually displayed. E-F3 ERROR F3 Request-to-recive time up error E-F4 ERROR F4 Receive command error E-F5 ERROR F5 E-F6 ERROR F6 E-F7 ERROR F7 NACK code receiving error Data requested for needle position can not be returned. It is not receive command for the request one. E-F8 ERROR F8 PRE code error E-F9 ERROR F9 No applicable command E-FA ERROR FA Interface receive data sum check error E-FB ERROR FB E-FF ERROR FF Send time up error No status is returned from main shaft, lower shaft motor, or CPU. BES-941BC • BES-1241BC 163