Brother International HL-1260 Service Manual - Page 149
Scanner Unit, Cartridge Stopper Assy
View all Brother International HL-1260 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 149 highlights
1.10 Scanner Unit (1) Unplug the LD PCB harness (scanner flat cable) connector (6P), and polygon harness (5P). (2) Remove the beam from the body by loosening the screws. (3) Remove the scanner unit from the body by loosening the screws. Caution: Do not disassemble the scanner unit, it can be only adjusted at the factory. Scanner unit Screws Screws Beam Polygon harness 5P Scanner flat cable 6P 1.11 Cartridge Stopper Assy Figure 4.8 (1) Loosen 4 screws and remove the scanner mount plate in the direction of the arrow (the ground leaf spring is also released at the same time.) (2) Release the hook by bending the arm of the cartridge stopper assy ( A ), slide the cartridge stopper assy to the left ( B ) and the remove the cartridge stopper assy ( C ). Rear Ground leaf spring Screws Right side Scanner mount plate Left side Cartridge stopper assy Figure 4.9 Cartridge stopper assy Scanner mount plate B C A Front Figure 4.10 IV - 5