Brother International HL-1260 Service Manual - Page 89
COVER OPEN is displayed even if the upper cover is closed
View all Brother International HL-1260 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 89 highlights
M-4 Malfunction of control panel switches. Possible cause Step Check Result Remedy Mis-operation 1 Are the switchs operated according to the operation manual? No Operate the switches correctly following the operation manual. Switch 2 Control panel PCB Switch flat cable Main PCB When a switch is pressed,does the voltage of Yes the following signals change from 5V to 0V? Signal No Main PCB Panel PCB SW8(SEL) P1-8 --- P1-14 SW7(MODE/EMULATION) P1-10 --- P1-12 SW6(FONT/ECONOMY) P1-12 --- P1-10 SW5(FORM FEED/FEEDER) P1-14 --- P1-8 SW4(SET/COPY) P1-16 --- P1-6 SW3(CONTINUE/SHIFT) P1-18 --- P1-4 SW2(DOWN/RESET) P1-20 --- P1-2 SW1(UP/TEST) P1-21 --- P1-1 Replace the Main PCB assy. Replace the control panel unit or the switch flat cable. M-5 Malfunction of buzzer Possible cause Step Check Result Remedy Operational error Main PCB Buzzer 1 Is the "Buzzer on mode "selected according No to the operation manual? (To alternate the buzzer on/off mode selection, press the MODE switch and select the "Advanced mode ".) Set the buzzer on mode. 2 Check the buzzer signal with a oscilloscope. Is the pulse of 4KHz output? Yes Replace the main PCB assy. No Replace the main PCB assy. M-6 "12 COVER OPEN" is displayed even if the upper cover is closed Possible cause Step Check Result Remedy Upper cover Main PCB 1 Does the upper cover hook press the actuator No Replace the upper cover assy. of the interlock switch on the main PCB correctly when upper cover is closed? Yes Replace the main PCB assy. VI - 12