SESC i S BStatus information request
![]() |
View all Brother International RJ-3050Ai manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 102 highlights
ESC/P Command Reference ESC i S Status information request ASCII: ESC i S Decimal: 27 105 83 Hexadecimal: 1B 69 53 Parameters None Description Sends a requests for the printer status. The printer status consists of 32 bytes. Order 1 2 3 4 Offset 0 1 2 3 Size 1 1 1 1 Name Print head mark Size Brother code Series code 5 4 1 Model code 6 5 7 6 8 7 9 8 10 9 11 10 12 11 13 12 14 13 15 14 16 15 17 16 18 17 19 18 20 19 21 20 22 21 23 22 24 23 25 24 1 Country code 1 Battery level information 1 Reserved 1 Error information 1 1 Error information 2 1 Media width 1 Media type 1 Number of colors 1 Media length (higher order bytes) 1 Media sensor value 1 Mode 1 Density 1 Media length (lower order bytes) 1 Status type 1 Phase type 1 Phase number (higher order bytes) 1 Phase number (lower order bytes) 1 Notification number 1 Expansion area (number of bytes) 8 Reserved Value/Standard Fixed at 80h Fixed at 20h Fixed at "B" (42h) Fixed at "7" (37h) RJ-3050: Fixed at "3" (33h) RJ-3150: Fixed at "4" (34h) Fixed at "0" (30h) Refer to table (5) below. Fixed at 00h Refer to table (1) below. Refer to table (2) below. Refer to "3.1 Print area" on page 11. Refer to table (3) below. Fixed at 00h Refer to "3.1 Print area" on page 11. Not used Fixed at 00h Fixed at 00h Refer to "3.1 Print area" on page 11. Refer to table (4) below. Fixed at 00h Fixed at 00h Fixed at 00h Not used Fixed at 00h Fixed at 00h - 96 - 5. Control Command Details