Brother International RJ-3050Ai ESC/ P Command Reference - Page 117
ESC iXj1, Retrieve default international character set
View all Brother International RJ-3050Ai manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 117 highlights
ESC iXj1 Retrieve default international character set ASCII: ESC i X Decimal: 27 105 88 Hexadecimal: 1B 69 58 j 1 n1 n2 106 49 n1 n2 6A 31 n1 n2 Parameters n1: 00h (Fixed) n2: 00h (Fixed) Description The default international character set setting is returned as 3-byte data. [1] 01h (Fixed) [2] 00h (Fixed) [3] Setting 00h: U.S.A. 01h: France 02h: Germany 03h: U.K. 04h: Denmark I 05h: Sweden 06h: Italy 07h: Spain I 08h: Japan 09h: Norway 0Ah: Denmark II 0Bh: Spain II 0Ch: Latin America 0Dh: South Korea 40h: Legal The retrieved value is a value specified by a static command. ESC/P Command Reference - 111 - 5. Control Command Details
ESC/P Command Reference
- 111 -
5. Control Command Details
ESC iXj1
Retrieve default international character set
ASCII:
ESC
i
X
j
1
n1
n2
Decimal:
27
105
88
106
49
n1
n2
Hexadecimal: 1B
69
58
6A
31
n1
n2
Parameters
n1: 00h (Fixed)
n2: 00h (Fixed)
Description
The default international character set setting is returned as 3-byte data.
[1] 01h (Fixed)
[2] 00h (Fixed)
[3] Setting
00h: U.S.A.
01h: France
02h: Germany
03h: U.K.
04h: Denmark I
05h: Sweden
06h: Italy
07h: Spain I
08h: Japan
09h: Norway
0Ah: Denmark II
0Bh: Spain II
0Ch: Latin America
0Dh: South Korea
40h: Legal