C (VR604) CHAPTER 10 TROUBLESHOOTING Control panel PCB C (R614) Figure 10-202B (PC400/FC200) b. After Replacing the Scanning Lamp Unit, Intensity Sensor, or AE Sensor (Before Adjustment) • If the scanning lamp has blackened, replace it. • Clean the scanning system (lens array, lamp reflector, lamp). 1) Set the cartridge to the copier. 2) De-select AE, and set the copy density control lever/dial to the center. 3) Set the density correction switch (SW606) to the center (PC420/430/FC220). 4) Set the Test Sheet (NA3/NB3/NA2), and make a copy. 5) Check if the copy is free of fogging, and gray scale No. 9 (No. 10, if NB3) is some- what visible. • If too dark, Turn VR604 on the control panel PCB clockwise slightly to increase the intensity. • If too light, Turn VR604 counterclockwise slightly to decrease the intensity. 6) Repeat steps 4) and 5) until the density is optimum. Notes: After adjusting the intensity, be sure to adjust the AE mechanism (PC420/430/FC220). COPYRIGHT © 1998 CANON INC. CANON PC400/420/430,FC200/220 REV.0 JAN.1998 PRINTED IN JAPAN (IMPRIME AU JAPON) 10-7