Canon PC400 Service Manual - Page 69
Operations in Measurement Mode, Operations during Copying
View all Canon PC400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
CHPTER 4 IMAGE FORMATION SYSTEM 2. Operations a. Operations in Measurement Mode HVTDC=1, DCTPWM=0 Oscillation circuit goes ON. Constant current control circuit generates 'ON'. TREV=1 Measurement mode is selected, applying a constant current to the transfer charging roller. Positive bias control circuit goes OFF. High-voltage transformer/rectifier circuit goes OFF. In measurement mode, the current is monitored by the current sensor circuit so that the constant current control circuit can control it to a constant current. Further, the microprocessor monitors the internal resistance of the transfer charging roller in terms of voltage using the auxiliary winding of the transformer (T107). b. Operations during Copying HVTDC=1, DCTPWM=1 Oscillation circuit goes ON. Pulse/DC converter circuit goes ON. Voltage control circuit goes ON. TREV=1 Positive bias control circuit goes OFF. Multiplier/rectifier circuit goes OFF. High-voltage transformer (T107) goes ON to apply a negative DC bias to the transfer charging roller. COPYRIGHT © 1998 CANON INC. CANON PC400/420/430,FC200/220 REV.0 JAN.1998 PRINTED IN JAPAN (IMPRIME AU JAPON) 4-11