Canon UHD DIGISUPER 90 manual for UJ27x6.5B - Page 120

Setting the iris close detection to ON/OFF, Setting the tally lamp ON/OFF

Page 120 highlights

[Iris]­- Close Setting the iris close detection to ON/OFF This iris cannot be closed when the extender (2.0x) is inserted while the iris correction function is set to ON. To compensate for this, a function which closes the iris when iris close has been detected can be set. Top screen TAL Setting the tally lamp ON/OFF Top screen [Zoom]­- Movement Setting the zoom servo start characteristics Start Setting the zoom servo stop characteristics Stop Setting the zoom mechanism end stop characteristics End Top screen × 2, Zoom screen Iris screen × 3 or to select (to set to ON) * This appears and iris close detection takes effect when ON is selected as the Comp setting (iris correction). *(Note): Depending on the camera, it may not be possible for the iris to operate properly due to the interaction between the iris correction function of the lens and the iris control exercised from the camera. At such a time, set the iris close detection to OFF. Selection item ON OFF Function Iris close detection No iris close detection Default value: This is set according to the camera interface at the factory prior to shipment. Selection item Function or to select (flashing) (to set to OFF) (D) ON Lighted OFF Extinguished (D): Default value Movement screen Selection item Function E6 to set the servo start characteristics to set the servo stop characteristics to set the mechanism end stop characteristics (to set the servo start characteristics) to adjust (to set to "48") 00 - 99 Slow start Quick start Servo start characteristics default value: 50 Servo stop characteristics default value: 50 Mechanism end stop characteristics default value: 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144

E6
[Iris] – Close
Setting the iris close detection to ON/OFF
This iris cannot be closed when the extender (2.0x) is inserted
while the iris correction function is set to ON. To compensate for
this, a function which closes the iris when iris close has been
detected can be set.
Top screen
Iris screen
× 3
or
to select
(to set to ON)
*
This appears and iris close
detection takes effect when ON
is selected as the Comp setting
(iris correction).
*(Note):
Depending on the camera, it may not be possible for the iris to operate
properly due to the interaction between the iris correction function of the
lens and the iris control exercised from the camera. At such a time, set the
iris close detection to OFF.
Selection item
ON
OFF
Function
Iris close detection
No iris close detection
Default value: This is set according to the camera interface at the factory prior to shipment.
TAL
Setting the tally lamp ON/OFF
Top screen
or
(flashing)
to select
(to set to OFF)
Selection item
(D)
ON
OFF
Function
Lighted
Extinguished
(D): Default value
[Zoom] – Movement
Setting the zoom servo start characteristics
Start
Setting the zoom servo stop characteristics
Stop
Setting the zoom mechanism end stop characteristics
End
Top screen
× 2,
Zoom screen
Movement
screen
to set the servo start
characteristics
to set the servo stop
characteristics
to set the mechanism end
stop characteristics
(to set the servo start
characteristics)
to adjust
(to set to “48”)
Selection item
00
99
Function
Slow start
Quick start
Servo start characteristics default value: 50
Servo stop characteristics default value: 50
Mechanism end stop characteristics default value: 99