Canon XA45 XA40 XA45 Instruction Manual - Page 65

Setting the Time Code's Initial Value, SDI/HDMI Scan Mode]

Page 65 highlights

Setting the Time Code Setting the Time Code's Initial Value If you set the running mode to [ Preset], you can set the initial value of the time code. 1 Select [Initial Time Code]. > [3 # Recording Setup] > [Initial Time Code] • The time code setting screen appears with an orange selection frame indicating the hours. • Select [Reset] to reset the time code to [00:00:00:00] and return to the previous screen. If the running mode is set to [ Free Run], the time code will be reset the moment you select the 65 button and keep running continuously from 00:00:00:00. 2 Select [Í] or [Î] to set the value for the hours and then select the minutes field. • Change the rest of the fields (minutes, seconds, frame) in the same way. 3 After completing all the fields of the time code, select [OK]. • Select [Cancel] to close the screen without changing the time code. • If the running mode is set to [ Free Run], the time code will start running from the time code entered the moment you select [OK]. 4 Select [X]. NOTES • When the frame rate is set to 23.98P, the frames value in the time code runs from 0 to 23. For other settings, it runs from 0 to 29. • However, if > [£ Display Setup] > [SDI/HDMI Scan Mode] (s only) or [HDMI Scan Mode] (t only) is set to [ PsF (Forced 1080i)], even when the frame rate is set to 23.98P, the frames value of the time code output from the SDI OUT terminal (s only) and HDMI OUT terminal will be converted so it runs from 0 to 29. • You can use the > [3 Recording Setup] > [HDMI Time Code] setting to turn time code output from the HDMI OUT terminal on or off. • When slow & fast motion recording is activated, you cannot select the [ Free Run] running mode. Conversely, when pre-recording is activated, [ Free Run] is set automatically and cannot be changed. • When slow & fast motion recording is activated, the time code signal cannot be output from the SDI OUT terminal (s only) or HDMI OUT terminal. • When you are using the [ Free Run] running mode, the time code will continue running as long as the built-in backup battery has some charge left, even if you disconnect all other power sources. However, this is less accurate than when the camcorder is on.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141

Setting the Time Code
65
Setting the Time Code’s Initial Value
If you set the running mode to [
Preset], you can set the initial value of the time code.
1
Select [Initial Time Code].
>
[
3
#
Recording Setup]
>
[Initial Time Code]
The time code setting screen appears with an orange selection frame indicating the hours.
Select [Reset] to reset the time code to [00:00:00:00] and return to the previous screen. If the
running mode is set to [
Free Run], the time code will be reset the moment you select the
button and keep running continuously from 00:00:00:00.
2
Select [
Í
] or [
Î
] to set the value for the hours and then select the minutes field.
Change the rest of the fields (minutes, seconds, frame) in the same way.
3
After completing all the fields of the time code, select [OK].
Select [Cancel] to close the screen without changing the time code.
If the running mode is set to [
Free Run], the time code will start running from the time code
entered the moment you select [OK].
4
Select [
X
].
NOTES
When the frame rate is set to 23.98P, the frames value in the time code runs from 0 to 23. For other
settings, it runs from 0 to 29.
However, if
>
[
£
Display Setup]
>
[SDI/HDMI Scan Mode] (
s
only) or [HDMI Scan
Mode] (
t
only) is set to [
PsF (Forced 1080i)], even when the frame rate is set to 23.98P,
the frames value of the time code output from the SDI OUT terminal (
s
only) and HDMI OUT
terminal will be converted so it runs from 0 to 29.
You can use the
>
[
3
Recording Setup]
>
[HDMI Time Code] setting to turn time code
output from the HDMI OUT terminal on or off.
When slow & fast motion recording is activated, you cannot select the [
Free Run] running
mode. Conversely, when pre-recording is activated, [
Free Run] is set automatically and
cannot be changed.
When slow & fast motion recording is activated, the time code signal cannot be output from the SDI
OUT terminal (
s
only) or HDMI OUT terminal.
When you are using the [
Free Run] running mode, the time code will continue running as
long as the built-in backup battery has some charge left, even if you disconnect all other power
sources. However, this is less accurate than when the camcorder is on.