Cisco WS-X4515 Hardware Maintenance Manual - Page 109
Side view, SIMM inserted, Top view, on the socket. See
UPC - 746320659190
View all Cisco WS-X4515 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 109 highlights
Figure 5-10 Inserting Shared-Memory SIMMs Top view Push the SIMM down and back Memory Replacement Procedures Polarization notch Side view, SIMM inserted Push the SIMM down and back H1052a The socket guide posts insert through the SIMM holes (on both sides) Step 7 To insert a SIMM, angle it into position, then carefully push down and back on the edges, holding each edge so that it securely snaps in place. (See Figure 5-10.) When it snaps into place, the two metal holders clip over the edge of the SIMM, and it sits horizontally. Caution Avoid damage to the SIMMs and SIMM socket by not handling them roughly. The SIMMs are also sensitive to ESD damage. Step 8 Check that the SIMM is straight and that the holes are aligned with the socket guide posts on the socket. (See Figure 5-10.) If you are done with all SIMM replacement procedures, proceed to the section "Replacing Network Processor Modules" earlier in this chapter. Maintaining and Upgrading the Router 5-15